Dose Calibrator Linearity Testing Using an Improved Attenuator System
نویسندگان
چکیده
Nuclear Regulatory Commission (NRC) guidelines state that dose calibrators must be tested for linearity upon installation and quarterly thereafter over a range of activities from 10 ~J,Ci (370 kBq) to the highest dose administered to the patient (300 mCi [11.1 GBq] ofiodine-131 for therapy at our institution). The simplest method of linearity testing utilizes commercial attenuator kits. These kits consist of different attenuator tubes plus a central tube that remains in the dose calibrator during the entire testing process. The disadvantage of these kits is that the test has to be performed twice, once with a high activity source and a second time with a lower activity source, to cover the full range of activities required by the NRC. We have designed two accessory tubes that can be used in conjunction with a commercial attenuator system, thereby covering the range of activity required by the NRC with a single source of technetium-99m. It takes less than 4 min to complete the entire measurement with this improved linearity test kit.
منابع مشابه
Quality Control Testing of Dose Calibrators
We have reviewed quality control testing of dose calibrators and have analyzed the potential for error. The uncertainty in half-lives of reference sources can lead to inaccurate assessment of the accuracy and constancy in dose calibrator performance. Molybdenum-99 contamination of '"Tc used as a reference source can appear as a nonlinear response of the dose calibrator. The useful life of a ref...
متن کاملGFR Determination by a Modification of the Gates Method: The Conventional Renal Examination with a Semi-Automated GFR Measurement
The conventional radionuclide renal examination using a 1020-mCi dose of technetium-99m t mTc) DTPA (Pentetate), conducted over a 30-60-min duration, does not accommodate the Gates method for GFR determination. Simple modifications to the Gates technique will, however, permit a GFR determination to be made without sacrificing the components of a complete conventional renal examination, and will...
متن کاملDose calibrator linearity test: 99mTc versus 18F radioisotopes*
OBJECTIVE The present study was aimed at evaluating the viability of replacing (18)F with (99m)Tc in dose calibrator linearity testing. MATERIALS AND METHODS The test was performed with sources of (99m)Tc (62 GBq) and (18)F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical (99m)Tc and (18)F sources activities were...
متن کاملImproving Linearity of CMOS Variable-gain Amplifier Using Third-order Intermodulation Cancellation Mechanism and Intermodulation Distortion Sinking Techniques
This paper presents an improved linearity variable-gain amplifier (VGA) in 0.18-µm CMOS technology. The linearity improvement is resulted from employing a new combinational technique, which utilizes third-order-intermodulation (IM3) cancellation mechanism using second-order-intermodulation (IM2) injection, and intermodulation distortion (IMD) sinking techniques. The proposed VGA gain cell co...
متن کاملکنترل کیفی و کالیبراسیون دستگاه های دزکالیبراتور RAMS-88 در مراکز پزشکی هسته ای ایران
The aim of this paper is the examining ways for quality control and calibration of Rams-88 calibrator. The device measures the amount of &gamma and &beta rays in radio medicines by means of the amount of radioactivity of radio nuclide. In this paper experiments has been done for explaining correct operation of these devices using standard method including precision, accuracy and linearit...