Screen-printed ultrasonic 2-D matrix array transducers for microparticle manipulation.

نویسندگان

  • Yongqiang Qiu
  • Han Wang
  • Sylvia Gebhardt
  • Aleksandrs Bolhovitins
  • Christine E M Démoré
  • Andreas Schönecker
  • Sandy Cochran
چکیده

This paper reports the development of a two-dimensional thick film lead zirconate titanate (PZT) ultrasonic transducer array, operating at frequency approximately 7.5MHz, to demonstrate the potential of this fabrication technique for microparticle manipulation. All layers of the array are screen-printed then sintered on an alumina substrate without any subsequent patterning processes. The thickness of the thick film PZT is 139±2μm, the element pitch of the array is 2.3mm, and the dimension of each individual PZT element is 2×2mm(2) with top electrode 1.7×1.7mm(2). The measured relative dielectric constant of the PZT is 2250±100 and the dielectric loss is 0.09±0.005 at 10kHz. Finite element analysis was used to predict the behaviour of the array and to optimise its configuration. Electrical impedance spectroscopy and laser vibrometry were used to characterise the array experimentally. The measured surface motion of a single element is on the order of tens of nanometres with a 10Vpeak continuous sinusoidal excitation. Particle manipulation experiments have been demonstrated with the array by manipulating Ø10μm polystyrene microspheres in degassed water. The simplified array fabrication process and the bulk production capability of screen-printing suggest potential for the commercialisation of multilayer planar resonant devices for ultrasonic particle manipulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acoustic Devices for Particle and Cell Manipulation and Sensing

An emerging demand for the precise manipulation of cells and particles for applications in cell biology and analytical chemistry has driven rapid development of ultrasonic manipulation technology. Compared to the other manipulation technologies, such as magnetic tweezing, dielectrophoresis and optical tweezing, ultrasonic manipulation has shown potential in a variety of applications, with its a...

متن کامل

Simulation and Experimental Analysis of Mechanical Crosstalk in an Ultrasonic Matrix Array

The phenomenon known as mechanical crosstalk from the point of view of its physical nature and the causes of its generation are analyzed. It is also analyzed how it may affect the performance of ultrasonic matrix arrays. This phenomenon occurs primarily in matrix arrays and it is magnified by certain factors causing serious problems in the performance of this type of transducers. This work incl...

متن کامل

Contribution of dislocation dipole structures to the acoustic nonlinearity

Related Articles Microparticle trapping in an ultrasonic Bessel beam Appl. Phys. Lett. 99, 233704 (2011) The study of new vacuum pressure measurement technique using ultrasonic acoustic impedance transducers Rev. Sci. Instrum. 82, 075111 (2011) Resonant ultrasound spectroscopy of cylinders over the full range of Poisson's ratio Rev. Sci. Instrum. 82, 035105 (2011) A novel method for digital ult...

متن کامل

A MEMS Phased Array Transducer for Ultrasonic Flaw Detection

Metal structures can fail because of fatigue crack propagation or because of section loss from corrosion. Regular inspection is required to detect such failures. We report here progress toward the development of MEMS-based transducers for ultrasonic flaw detection, to be permanently mounted at critical locations on structures. In a complete system, a single piezoelectric element will be used to...

متن کامل

Flexible transistor active matrix array with all screen-printed electrodes

Flexible transistor active matrix array is fabricated on PEN substrate using all screen-printed gate, source and drain electrodes. Parylene-C and DNTT act as gate dielectric layer and semiconductor, respectively. The transistor possesses high mobility (0.33 cm 2 V -1 s -1 ), large on/off ratio (> 10 6 ) and low leakage current (~10 pA). Active matrix array consists of 10×10 transistors were dem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasonics

دوره 62  شماره 

صفحات  -

تاریخ انتشار 2015