Gold-coated NIR stents in porcine coronary arteries.
نویسندگان
چکیده
BACKGROUND As endovascular stents are altered to add functionality, eg, by adding radiopaque coatings, biocompatibility may suffer. METHODS AND RESULTS We examined the vascular response in porcine coronary arteries to stainless steel gold-coated NIR stents (7-cell, Medinol, Inc). Stents, 9 and 16 mm in length, were left bare or coated with a 7-microm layer of gold. Physical and material effects were examined in four different gold-coated stent types, two at each length that either had the coating applied to the standard strut, ie, gold coated thicker than controls, or had the coating applied to thinned struts, ie, gold coated of the same thickness as control struts. Simple gold coating exacerbated intimal hyperplastic and inflammatory reactions over 28 days, but postplating thermal processing smoothed the coating surface and negated the adverse tissue response to gold. The relative amounts of base steel and gold coating and their resistances to expansion and collapse determined the extent of stent recoil. CONCLUSIONS Gold coatings enhance the radiopacity of steel stents, but not without effects on vascular repair. Material effects predominate and can be abrogated by heating coated stents to alter surface finish and material purity. Clinical results may suffer unless consideration is given to material and physical effects of gold.
منابع مشابه
New frontiers in cardiology: drug-eluting stents: Part II.
Preclinical Data Unlike other antimitotic agents, paclitaxel shifts the cytoskeleton equilibrium toward assembly, leading to reduced vascular cell proliferation, migration, and signal transduction.2 Paclitaxel is highly lipophilic, resulting in a rapid cellular uptake and a long-lasting effect in the cell.3 NIR stents (Boston Scientific Corp) coated with poly(lactide-co-caprolactone) copolymer ...
متن کاملMethotrexate loaded SAE coated coronary stents reduce neointimal hyperplasia in a porcine coronary model.
OBJECTIVE To evaluate the effect of stent based methotrexate delivery on neointimal hyperplasia. METHODS Stainless steel coronary stents and biological polymer coated (SAE) stents were randomly implanted in coronary arteries of pigs with a stent to artery ratio of 1.1:1. The pigs were killed after five days (10 stents) or four weeks (20 stents). Second, stainless steel coronary stents were di...
متن کاملNovel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.
BACKGROUND Biodegradable polymer-coated stents may have positive effects on arterial healing, and reduce the need for prolonged antiplatelet therapy. AIM To assess the vascular effects of the biodegradable polymer proposed as a stent coating, as well as to evaluate inhibition of intimal hyperplasia by Biodegradable Polymer-Coated Paclitaxel-Eluting Stents (BP-PES, LUC-Chopin, Balton) in porci...
متن کاملHuman recombinant activated protein C-coated stent for the prevention of restenosis in porcine coronary arteries
Activated protein C (APC), an endogenous protein, inhibits inflammation and thrombosis and interrupts the coagulation cascade. Here, we investigated the effect of human recombinant APC on the development of neointimal hyperplasia in porcine coronary arteries. Yukon Choice bare metal stents were coated with 2.6 µg APC/mm(2). Under general anesthesia, APC-coated and bare stents were implanted in ...
متن کاملEffect of Stents Coated with Artemisinin or Dihydroartemisinin in a Porcine Coronary Restenosis Model
BACKGROUND AND OBJECTIVES Artemisinin and dihydroartemisinin are drugs used to treat malaria. These drugs suppress inflammatory reactions. The aim of this study was to examine the anti-intima hyperplasia effect of a novel drug-eluting stent with artemisinin or dihydroartemisinin in a porcine coronary restenosis model. MATERIALS AND METHODS Pigs were randomized into four groups; in the first, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 103 3 شماره
صفحات -
تاریخ انتشار 2001