Quantitative ex vivo and in vivo comparison of lumen dimensions measured by optical coherence tomography and intravascular ultrasound in human coronary arteries.

نویسندگان

  • Nieves Gonzalo
  • Patrick W Serruys
  • Héctor M García-García
  • Gijs van Soest
  • Takayuki Okamura
  • Jurgen Ligthart
  • Michiel Knaapen
  • Stefan Verheye
  • Nico Bruining
  • Evelyn Regar
چکیده

INTRODUCTION AND OBJECTIVES The relationship between the lumen dimensions obtained in human coronary arteries using intravascular ultrasound (IVUS) and those obtained using optical coherence tomography (OCT) is not well understood. The objectives were to compare the lumen measurements obtained ex vivo in human coronary arteries using IVUS, OCT and histomorphometry, and in vivo in patients using IVUS and OCT with and without balloon occlusion. METHODS Ex vivo study: the lumen areas of matched anatomical sections of human coronary arteries were measured using IVUS, OCT and histology. In vivo study: the lumen areas in matched sections were measured using IVUS and OCT with and without occlusion. RESULTS Ex vivo: in the eight specimens studied, the lumen area obtained using OCT and IVUS was larger than that obtained using histomorphometry: mean difference 0.8+/-1 mm(2) (28%) for OCT and 1.3+/-1.1 mm(2) (40%) for IVUS. In vivo: in the five vessels analyzed, the lumen area obtained using IVUS was larger than that obtained using OCT: mean difference 1.67+/-0.54 mm(2) (33.7%) for IVUS relative to OCT with occlusion and 1.11+/-0.53 mm(2) (21.5%) relative to OCT without occlusion. The lumen area obtained using OCT without occlusion was larger than that obtained using OCT with occlusion: mean difference 0.61+/-0.23 mm(2) (13%). CONCLUSIONS In fixed human coronary arteries, both IVUS and OCT overestimated the lumen area compared with histomorphometry. In vivo the lumen dimensions obtained using IVUS were larger than those obtained using OCT, with or without occlusion. Moreover, the OCT image acquisition technique (i.e. with or without occlusion) also had an impact on lumen measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative precision of optical frequency domain imaging: direct comparison with frequency domain optical coherence tomography and intravascular ultrasound

No systematic validation study is available with optical frequency domain imaging (OFDI), directly compared with frequency domain optical coherence tomography (FD-OCT) and intravascular ultrasound (IVUS). Controversy also remains about the impact of different stent contour tracing methods by OFDI/FD-OCT. In vitro: coronary phantom models (1.51-5.04 mm) were imaged with OFDI, FD-OCT, and IVUS, d...

متن کامل

Trimodality imaging system and intravascular endoscopic probe: combined optical coherence tomography, fluorescence imaging and ultrasound imaging.

In this Letter, we present a trimodality imaging system and an intravascular endoscopic probe for the detection of early-stage atherosclerotic plaques. The integrated system is able to acquire optical coherence tomography (OCT), fluorescence, and ultrasound images and simultaneously display them in real time. A trimodality intravascular endoscopic probe of 1.2 mm in diameter and 7 mm in length ...

متن کامل

Comparison between optical coherence tomography and intravascular ultrasound in detecting neointimal healing patterns after stent implantation.

BACKGROUND The amount of data comparing intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for the detection of stent coverage in clinical settings is limited. AIM To make a qualitative and quantitative assessment of the vascular healing patterns in patients after stent implantations visualised by both IVUS and OCT. METHODS Images were obtained in patients with clinical ...

متن کامل

Point of View Intravascular Ultrasound : A Histological Study of Vessels During Life

uring the last several years, dramatic developD ments have taken place in the area of cardiac imaging techniques. From an era of imaging by silhouettes (chest roentgenography, fluoroscopy, angiocardiography, angiography), we have emerged into an era of imaging by tomographic scanning (echocardiography, radionuclide and computed tomography, magnetic resonance).l-3 Two-dimensional intravascular e...

متن کامل

Optical Coherence Tomography in Coronary Atherosclerosis

Despite developments in therapeutic and diagnostic technologies, the global burden of atherosclerotic coronary artery disease is increasing. Intravascular imaging has become an invaluable adjunct to percutaneous coronary intervention. Optical coherence tomography (OCT) is a catheter based invasive imaging system that uses light instead of ultrasound to produce high resolution in vivo images of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 62 6  شماره 

صفحات  -

تاریخ انتشار 2009