Localization of Fiducial Skin Markers in MR Images using XXX for PET/MRI Nonrigid Breast Image Registration

نویسندگان

  • Derek Walvoord
  • Karl G. Baum
  • María Helguera
  • Andrzej Krol
  • Roger Easton
چکیده

In most instances, multiple-modality visualization of pathologies will present advantages over single-modality studies. For many medical imaging procedures, it is desirable to produce a “fused” output that simultaneously exhibits characteristics of the data from each individual modality to reduce the difficulty of the decision-making process for radiologists. Preprocessing for most data fusion algorithms typically performs the necessary registration of the input data (from each modality). Fiducial markers may be used to display image locations that are common to each modality if the images exhibit very different spatial structure, as is the case with MRI and PET imagery. The process of automating the detection of these markers needs more investigation in the medical field, and the current state of the art often requires manual selection by a human observer throughout the 3dimensional image stack. The objective of automated detection is to locate the centroid of each marker in a noisy background that contains additional objects that span a large range of intensity values. The correlation methods employed must somehow “normalize” the images to accommodate changes in the input image, so that “brightness” of the region does not affect the correlation, thus reducing the false positive rate. The filter should accommodate within-class distortion, as the size and shape of the fiducial marker will vary through the image stack. For this work, a mean-subtracted MACH filter was constructed and applied to data that are mean-subtracted locally. The location of centroids in the output stack of correlation planes was determined by applying morphological operations to extract regions-of-interest. It is apparent that a relatively high probability of detection is obtained over a wide range of thresholds with an acceptable false positive rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite-element method for intermodality nonrigid breast registration using external skin markers

We are developing a method using nonrigid co-registration of PET and MR breast images as a way to improve diagnostic specificity in difficult-to-interpret mammograms, and ultimately to avoid biopsy. A deformable breast model based on a finite-element method (FEM) has been employed. The FEM “loads” are taken as the observed intermodality displacements of several fiducial skin markers placed on t...

متن کامل

MRI/PET nonrigid breast-image registration using skin fiducial markers.

We propose a finite-element method (FEM) deformable breast model that does not require elastic breast data for nonrigid PET/MRI breast image registration. The model is applicable only if the stress conditions in the imaged breast are virtually the same in PET and MRI. Under these conditions, the observed intermodality displacements are solely due the imaging/reconstruction process. Similar stre...

متن کامل

Iterative Deformable FEM Model for Nonrigid PET/MRI Breast Image Coregistration

We implemented an iterative nonrigid registration algorithm to accurately combine functional (PET) and anatomical (MRI) images in 3D. Our method relies on a Finite Element Method (FEM) and a set of fiducial skin markers (FSM) placed on breast surface. The method is applicable if the stress conditions in the imaged breast are virtually the same in PET and MRI. In the first phase, the displacemen...

متن کامل

Roger P . Woods , John C . Mazziotta , and Simon R . Cherry MRI - PET Registration with Automated Algorithm

Objective: We have previously reported an automated method for withinmodality (e.g., PET-te-PET) image alignment. We now describe modifications to this method that allow for cross-modality registration of MRI and PET brain images obtained from a single subject. Methods: This method does not require fiducial markers and the user is not required to identify common structures on the two image sets...

متن کامل

Assessment of fiducial markers to enable the co-registration of photographs and MRI data.

PURPOSE To investigate the visualisation of novel external fiducial skin markers in photography and MRI. To co-register photographs and MR images, and additionally assess the spatial accuracy of these co-registrations with the view of future application in the investigation of forensically relevant soft tissue lesions. METHODS AND MATERIALS Strand-shaped fiducial markers were secured external...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009