Background—The recently reported Multicenter Automatic Defibrillator Implantation Trial (MADIT) showed improved survival in selected asymptomatic patients with coronary disease and nonsustained ventricular tachycardia. The economic consequences of defibrillator management in this patient population are unknown. Methods and Results—Patients were followed up to quantify their use of healthcare services, including hospitalizations, physician visits, medications, laboratory tests, and procedures, during the trial. The costs of these services, including the costs of the defibrillator, were determined in patients randomized to defibrillator and nondefibrillator therapy. Incremental cost-effectiveness ratios were calculated by relating these costs to the increased survival associated with the use of the defibrillator. The average survival for the defibrillator group over a 4-year period was 3.66 years compared with 2.80 years for conventionally treated patients. Accumulated net costs were $97 560 for the defibrillator group compared with $75 980 for individuals treated with medications alone. The resulting incremental cost-effectiveness ratio of $27 000 per life-year saved compares favorably with other cardiac interventions. Sensitivity analyses showed that the incremental cost-effectiveness ratio would be reduced to '$23 000 per life-year saved if transvenous defibrillators were used instead of the older devices, which required thoracic surgery for implantation. Conclusions—An implanted cardiac defibrillator is cost-effective in selected individuals at high risk for ventricular arrhythmias. (Circulation. 1998;97:2129-2135.)
منابع مشابه
The cost-effectiveness of automatic implantable cardiac defibrillators: results from MADIT. Multicenter Automatic Defibrillator Implantation Trial.
BACKGROUND The recently reported Multicenter Automatic Defibrillator Implantation Trial (MADIT) showed improved survival in selected asymptomatic patients with coronary disease and nonsustained ventricular tachycardia. The economic consequences of defibrillator management in this patient population are unknown. METHODS AND RESULTS Patients were followed up to quantify their use of healthcare ...
متن کاملThe Cost Effectiveness of Implantable Cardioverter-Defibrillators
OBJECTIVES We sought to evaluate the cost implications of the implantable cardioverter-defibrillator (ICD), using utilization, cost, and survival data from the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II. BACKGROUND This trial showed that prophylactic implantation of a defibrillator reduces the rate of mortality in patients who experienced a previous myocardial infarction ...
متن کاملCost-effectiveness of implantable cardioverter-defibrillators.
BACKGROUND Eight randomized trials have evaluated whether the prophylactic use of an implantable cardioverter-defibrillator (ICD) improves survival among patients who are at risk for sudden death due to left ventricular systolic dysfunction but who have not had a life-threatening ventricular arrhythmia. We assessed the cost-effectiveness of the ICD in the populations represented in these primar...
متن کاملImplantable cardioverter-defibrillators for primary prevention of sudden death in heart failure: are there enough bangs for the bucks?
The demonstrated efficacy of implantable cardioverterdefibrillators (ICDs) for reducing sudden death in heart failure trial populations presents a critical challenge to those responsible for the allocation of healthcare resources.1–3 The current cost, multiplied by the prevalence of heart failure deemed high-risk, threatens to make this one enterprise the highest priced intervention for the Med...
متن کاملCost-effectiveness of implantable defibrillators after myocardial infarction based on 8-year follow-up data (MADIT II).
OBJECTIVES About 190,000 Germans experience a myocardial infarction each year. Of these, 25% may be eligible for an implantable cardioverter defibrillator (ICD) due to low left ventricular ejection fraction. Given the high costs of implantation, the purpose of this study was to assess the cost-effectiveness of ICDs compared to conventional therapy in patients with an ejection fraction 30% or le...