Loudness functions with air and bone conduction stimulation in normal-hearing subjects using a categorical loudness scaling procedure.

نویسندگان

  • Stefan Stenfelt
  • Mehrnaz Zeitooni
چکیده

In a previous study (Stenfelt and Håkansson, 2002) a loudness balance test between bone conducted (BC) sound and air conducted (AC) sound was performed at frequencies between 0.25 and 4 kHz and at levels corresponding to 30-80 dB HL. The main outcome of that study was that for maintaining equal loudness, the level increase of sound with BC stimulation was less than that of AC stimulation with a ratio between 0.8 and 0.93 dB/dB. However, because it was shown that AC and BC tone cancellation was independent of the stimulation level, the loudness level difference did not originate in differences in basilar membrane stimulation. Therefore, it was speculated that the result could be due to the loudness estimation procedure. To investigate this further, another loudness estimation method (adaptive categorical loudness scaling) was here employed in 20 normal-hearing subjects. The loudness of a low-frequency and a high-frequency noise burst was estimated using the adaptive categorical loudness scaling technique when the stimulation was bilaterally by AC or BC. The sounds where rated on an 11-point scale between inaudible and too loud. The total dynamic range for these sounds was over 80 dB when presented by AC (between inaudible and too loud) and the loudness functions were similar for the low and the high-frequency stimulation. When the stimulation was by BC the loudness functions were steeper and the ratios between the slopes of the AC and BC loudness functions were 0.88 for the low-frequency sound and 0.92 for the high-frequency sound. These results were almost equal to the previous published results using the equal loudness estimation procedure, and it was unlikely that the outcome stems from the loudness estimation procedure itself. One possible mechanism for the result was loudness integration of multi-sensory input. However, no conclusive evidence for such a mechanism could be given by the present study. This article is part of a special issue entitled "MEMRO 2012".

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of categorical loudness scaling and its relation to threshold.

OBJECTIVE To further examine the reliability of categorical loudness scaling (CLS) for individual loudness categories and for the slope of the CLS functions. And, to evaluate the relationship between CLS and audiometric threshold. DESIGN CLS functions were obtained in 74 subjects, 58 with hearing loss and 16 with normal hearing. CLS functions were measured at three frequencies (1, 2, and 4 kH...

متن کامل

Loudness scaling revisited.

The present work was undertaken in an attempt to evaluate whether it is reasonable to expect that categorical loudness scaling can provide useful information for nonlinear hearing aid fitting. Normative data from seven scaling procedures show that the individual procedures relate the perceptual categories differently to sound level and with a substantial between-subject variance. Hearing-impair...

متن کامل

Auditory fMRI correlates of loudness perception for monaural and diotic stimulation

Loudness as the perceptual correlate of sound intensity is formed by some neural processing along the auditory pathway from the cochlea to the cortex. The loudness of a sound is largely determined by its level. Still, there are several other acoustical factors like stimulus bandwidth, duration, modulations, as well as personal factors like, e.g., the individual hearing status, that may affect p...

متن کامل

Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing

Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...

متن کامل

Estimates of loudness, loudness discomfort, and the auditory dynamic range: normative estimates, comparison of procedures, and test-retest reliability.

The purpose of this series of experiments was to establish normative reference values for absolute and relative judgements of loudness discomfort and for the auditory dynamic range (DR), and to evaluate intersubject variability and intra-subject test-retest reliability for the respective measures of loudness discomfort. To establish the normal auditory DR, audiometric thresholds and loudness di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hearing research

دوره 301  شماره 

صفحات  -

تاریخ انتشار 2013