Validation of Gating and Leukocyte Classification on Sysmex XE Series Automated Cell Counters

نویسندگان

  • Mari KONO
  • Tamiaki KONDO
  • Yuri TAKAGI
  • Atsushi WADA
  • Ian GILES
  • Kunihiro FUNAKOSHI
چکیده

− 1 − Leukocyte classification on Sysmex XE series hematology analyzers involves staining leukocytes with proprietory Polymethine Dye reagents that have affinity for nucleic acids. The outputs are two-dimensional scatter diagrams of side scatter and fluorescence intensity (DIFF scattergrams) subsequent to flow cytometric analysis of the stained cells. Leukocyte classification is based on the location of treated cells in the DIFF scattergram. Comparative methods for leukocyte typing can be done using monoclonal antibodies to CD antigens expressed on the cell surfaces. The present study investigates the relationship between cell-classification by means of CD antibodies versus cell classification on the Sysmex hematology analyzer. This was achieved by double staining cells with both CD antibodies and Sysmex cell counting reagents. Granulocytes, T and B lymphocytes, and monocytes were prepared using density gradient centrifugation and negative selection using magnetic cell sorting methods. Samples were peripheral blood samples from healthy human subjects. Isolated cells were stained with FITC-conjugated CD antibodies. Subsequently the same cells were incubated in Sysmex cell counting reagents in a way that mimics conditions used in the hematology cell counters. Post treatment, the cells were analyzed by flow cytometry (FCM), confocal laser scanning microscopy (CLSM), and electron microscopy (EM). FCM analysis revealed that most CD3and CD19-; CD14-; and CD16b-positive cells appeared in the lymphocyte; monocyte; and neutrophil gates on DIFF scattergrams. CLSM and EM observation shows characteristic morphological changes for each type of leukocyte, related to the degree of membrane disruption and nucleic acid distribution within the various cell types. This experimental approach appears to validate the method for classification of leukocytes on DIFF scattergrams versus classification on the basis of surface antigen labeling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.

Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in ...

متن کامل

Validation and implementation of an algorithm for reporting the automated absolute neutrophil count from selected flagged specimens.

Samples that are flagged by automated cell counters and, therefore, require a time-consuming microscopic review cause unacceptable wait times for patients in hematology/oncology clinics. We used a set of 518 samples to validate that 5 flags on Sysmex XE/XT instruments (Sysmex, Kobe, Japan) could safely be ignored when the absolute neutrophil count (ANC) was the primary clinical question. The R(...

متن کامل

Automation of bone marrow aspirate examination using the XE-2100 automated hematology analyzer.

BACKGROUND Attempts to analyze bone marrow aspirates have been reported with the use of several automated blood cell counters, but sufficient accuracy in examination is not acquired yet. Major problems have included difficulties in correctly differentiating various immature cells and interference by lipid in bone marrow aspirates. The goal of this study was to solve these problems to attain mor...

متن کامل

Evaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte

Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...

متن کامل

Automated counting of nucleated red blood cells in blood samples of newborns.

Nucleated red blood cells (NRBC) in blood samples interfere with the white blood cell (WBC) count on many types of automated haematology analysers. This makes it necessary to correct the WBC count by counting NRBC microscopically. This report describes the evaluation of two analysers, the Cell-Dyn 4000 and the Sysmex XE-2100, which use new techniques to recognize and enumerate NRBC. We conclude...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010