Cost-effectiveness of drug-eluting stents including the economic impact of late stent thrombosis.

نویسندگان

  • Kristian B Filion
  • Arup Michael Roy
  • Tara Baboushkin
  • Stéphane Rinfret
  • Mark J Eisenberg
چکیده

Recent studies examining the effectiveness of drug-eluting stents (DES) have found that the use of DES is associated with a significant increase in the incidence of late stent thrombosis (LST). Previous cost-effectiveness analyses of DES have not accounted for the costs associated with LST. In this study, published research was reviewed to identify studies that compared the cost-effectiveness of DES with that of bare-metal stents and to identify the incidence of LST. Probable costs were assigned to LST-related myocardial infarction and death on the basis of the treatment costs for these outcomes. These costs as well as those of extended clopidogrel therapy were then incorporated into the Sirolimus-Eluting Balloon Expandable Stent in the Treatment of Patients With De Novo Native Coronary Artery Lesions (SIRIUS) and TAXUS-IV cost-effectiveness data. This review found that the incidence of LST ranged from 0.2% to 0.7%. Assuming a base case LST incidence of 0.5%, a cost per death of $20,000, a cost per myocardial infarction of $20,000, and a cost of an additional 2 years of clopidogrel therapy of $2,428 per patient, the costs per revascularization avoided were $15,056 for the SIRIUS trial and $25,210 for the TAXUS-IV trial. The costs per quality-adjusted life-year gained were $250,935 and $257,591, respectively. Sensitivity analyses revealed that the costs per revascularization avoided varied from $14,618 to $15,830 for the SIRIUS trial and from $24,540 to $26,396 for the TAXUS-IV trial. Similarly, the cost per quality-adjusted life-year gained varied from $243,638 to $263,840 for the SIRIUS trial and from $250,739 to $269,708 for the TAXUS-IV trial. In conclusion, LST-related adverse events and the need for extended clopidogrel therapy substantially increase the costs associated with the implementation of DES. The inclusion of these costs renders the widespread use of DES not cost effective in the United States in terms of cost per quality-adjusted life-year gained and cost per revascularization avoided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel stent and drug elution technologies

To address concerns of late and very late stent thrombosis associated with first generation drug-eluting stent technology, novel approaches are being tested including stents with bioabsorbable polymers (including Biomatrix FlexTM, NoboriTM and SynergyTM), polymer-free drug delivery systems (including BiofreedomTM and Yukon®) and drug-eluting balloons (including Sequent PleaseTM, Dior® II and Pa...

متن کامل

Drug-eluting stents.

In their recent systematic review, Suzanne Ligthart and associates compared analyses of the cost-effectiveness of drug-eluting stents. They found that in most studies in which an incremental cost-effectiveness ratio greater than $50 000 per quality-adjusted life-year was calculated the study authors recommended against the widespread use of drug-eluting stents. However, we believe that previous...

متن کامل

Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention

OBJECTIVE To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. METHODS A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-ana...

متن کامل

Late thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials.

PURPOSE Drug-eluting stents are commonly used for percutaneous coronary intervention. Despite excellent clinical efficacy, the association between drug-eluting stents and the risk for late thrombosis remains imprecisely defined. METHODS We performed a meta-analysis on 14 contemporary clinical trials that randomized 6675 patients to drug-eluting stents (paclitaxel or sirolimus) compared with b...

متن کامل

Incredibly late thromboses in first generation drug eluting stents: a case series

BACKGROUND The drug-eluting stents have decreased the incidence of instent restenosis compared to bare metal stents. But, the incidence of late and very late stent thrombosis has increased with the drug-eluting stents. CASE PRESENTATION We are here, reporting three cases of incredibly late instent thrombosis, each one occurring after more than 50 months of drug-eluting stent placement. CONC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of cardiology

دوره 103 3  شماره 

صفحات  -

تاریخ انتشار 2009