Investigation of LC-Resonance Driving in Disconnector Bus-Transfer Testing

نویسندگان

  • Andreas Ritter
  • Ulrich Straumann
  • Uwe Riechert
  • Christian M Franck
چکیده

The ability to transfer load currents between parallel busbars is one of the main requirements for most disconnector switches in gas insulated as well as air insulated substations today. As such, the capability limits and testing methods are internationally standardized in IEC 62271-102. The test circuit dictated in this standard is the Thévenin equivalent of the high current, power frequency approximation of two parallel busbars supplied by an AC current source. This setup inevitably couples different factors influencing the bus-transfer switching process by directly specifying the preswitching current through the disconnector switch and recovery voltage expected across it after successful switching. To facilitate a more detailed and direct investigation of bus-transfer switching processes, a different test method is suggested and consequently implemented as a proof of concept. The suggested method entails the use of an AC current source to drive a current through two parallel impedances representing different sections of a busbar. The disconnector switch under test is placed in series with one of the impedances. In order to analyze the feasibility of such a setup, a proof of concept current source along with two parallel impedances was built. The main design goal for the current source was to provide AC currents over a large range of magnitudes at a constant frequency. In addition, the current provided by the source must not be influenced by the bus-transfer switching process. To fulfill these requirements, an LC-resonance circuit with an adjustable resonance frequency and a substantial initial energy storage capacity was chosen. Its applicability was verified in numerous switching cases of different specifications. The impedances representing substation busbars in the test setup were designed with a main focus on adjustability and precision. The resistance and inductance components were modelled after typical GIS substation values for lengths between 10 m and 600 m. Due to the conductor being comprised of overhead line cable, virtually any length in this range can be represented with minimal effort. Experimental verification has demonstrated that this type of test setup ensures direct comparability between laboratory tests and substation processes due to the ability to directly measure both parallel currents and the recovery voltage occurring at the disconnector after successful switching. This feature can prove beneficial for non-standard testing cases such as failure analysis and substation planning which require precise modelling of substation characteristics as well as sophisticated measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Derivation of Requirements for Small-current Switching in Future Hvdc Substations

As a central component of any existing AC substation, disconnector switches are responsible for providing isolation between grid-connected and safely approachable sections of bus. Additionally, they can provide the capability of transferring load currents between different busses. Due to the excellent performance history in AC, possible challenges for disconnector switches in future HVDC substa...

متن کامل

Analytical Study of Optical Bi-Stability of a Single-Bus Resonator Based on InGaAs Micro-Ring Array

In this paper, for the first time to our knowledge, we investigate the optical bi-stability in a compact parallel array of micro- ring resonators with 5μm radius, induced by optical nonlinearity. Due to the nature of perfect light confinement, resonance and accumulation process in a ring resonator, optical nonlinear effects, even at small optical power of a few milliwatts in this structure are ...

متن کامل

بررسی ارتباط شکست های شناختی شغلی با عملکرد ایمنی در رانندگان اتوبوس شهری

  Background and aims: Accidents and injuries are a cause for concern for all countries in the world. Cognitive failures can be defined as cognitive-based errors on simple tasks that a person should normally be able to complete without fault these mistakes include problems with memory, attention or action. The present study was designed to investigation of relationships between occupational cog...

متن کامل

An evaluation of Tehran intercity bus drivers’ vision compared with the standards for Iran and Europe

Background: With an ever-increasing number of vehicles on the road, it is inevitable that drivers will need to call upon an increasing use of sensory and motor skills in order to negotiate safely through traffic. Vision is one of the major senses in human beings, and it is definitely necessary for safe driving. Approximately 95% of the sensory input to the brain required for driving comes from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014