Erratum: Measurement of zinc stable isotope ratios in biogeochemical matrices by double-spike MC-ICPMS and determination of the isotope ratio pool available for plants from soil
نویسندگان
چکیده
Analysis of naturally occurring isotopic variations is a promising tool for investigating Zn transport and cycling in geological and biological settings. Here, we present the recently installed double-spike (DS) technique at the MAGIC laboratories at Imperial College London. The procedure improves on previous published DS methods in terms of ease of measurement and precisions obtained. The analytical method involves addition of a (64)Zn-(67)Zn double-spike to the samples prior to digestion, separation of Zn from the sample matrix by ion exchange chromatography, and isotopic analysis by multiple-collector inductively coupled plasma mass spectrometry. The accuracy and reproducibility of the method were validated by analyses of several in-house and international elemental reference materials. Multiple analyses of pure Zn standard solutions consistently yielded a reproducibility of about ±0.05‰ (2 SD) for δ(66)Zn, and comparable precisions were obtained for analyses of geological and biological materials. Highly fractionated Zn standards analyzed by DS and standard sample bracketing yield slightly varying results, which probably originate from repetitive fractionation events during manufacture of the standards. However, the δ(66)Zn values (all reported relative to JMC Lyon Zn) for two less fractionated in-house Zn standard solutions, Imperial Zn (0.10 ± 0.08‰: 2 SD) and London Zn (0.08 ± 0.04‰), are within uncertainties to data reported with different mass spectrometric techniques and instruments. Two standard reference materials, blend ore BCR 027 and ryegrass BCR 281, were also measured, and the δ(66)Zn were found to be 0.25 ± 0.06‰ (2 SD) and 0.40 ± 0.09‰, respectively. Taken together, these standard measurements ascertain that the double-spike methodology is suitable for accurate and precise Zn isotope analyses of a wide range of natural samples. The newly installed technique was consequently applied to soil samples and soil leachates to investigate the isotopic signature of plant available Zn. We find that the isotopic composition is heavier than the residual, indicating the presence of loosely bound Zn deposited by atmospheric pollution, which is readily available to plants.
منابع مشابه
Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS.
We report a method for the chemical purification of Pt from geological materials by ion-exchange chromatography for subsequent Pt stable isotope analysis by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using a 196Pt-198Pt double-spike to correct for instrumental mass bias. Double-spiking of samples was carried out prior to digestion and chemical separation to corre...
متن کاملAstrophysics of CAI formation as revealed by silicon isotope LA-MC-ICPMS of an igneous CAI
Silicon isotope ratios of a typical CAI from the Leoville carbonaceous chondrite, obtained in situ by laser ablation MC-ICPMS, together with existing Mg/Mg data, reveal a detailed picture of the astrophysical setting of CAI melting and subsequent heating. Models for the chemical and isotopic effects of evaporation of the molten CAI are used to produce a univariant relationship between PH2 and t...
متن کاملZinc isotope ratio imaging of rat brain thin sections from stable isotope tracer studies by LA-MC-ICP-MS.
Zinc stable isotope tracers (⁶⁷Zn and ⁷⁰Zn) were injected into rats at two different time points to investigate the feasibility of using tracers to study zinc kinetics at the microscale within distinct tissue features. Laser ablation coupled to multi-collector ICP-MS was used to analyse average isotope ratios in liver thin sections and to generate bio-images showing zinc isotope ratio distribut...
متن کاملApplication of isotopically labeled methylmercury for isotope dilution analysis of biological samples using gas chromatography/ICPMS.
An isotope dilution (ID) procedure for the determination of methylmercury (MMHg) in biological samples using an inductively coupled plasma mass spectrometer as detector after the capillary gas chromatographic separation (CGC/ICPMS) has been developed. For the first time, open-focused-microwave pretreatment has been used in conjunction with ID. Optimum conditions for the measurement of isotope r...
متن کاملSilicon Isotope Ratio Analysis of a Cai by Laser Ablation Mc-icpms and Implications for the Astrophysics of Cai Formation
Introduction: While it is well known that igneous CAIs tend to have high Si/Si and Mg/Mg relative to chondritic values, there have been few systematic studies that relate observed isotope fractionations in CAIs to their conditions and timescales of formation. Together with a wealth of information about the physical chemistry associated with evaporation and condensation of CAI-like liquids [1] w...
متن کامل