Semi-solid surface fluorometric analysis of glucose.

نویسندگان

  • S W Kiang
  • J W Kuan
  • G G Guilbault
چکیده

We describe an enzymatic fluorometric method for determining glucose concentrations in blood samples by analysis on a semi-solid surface (silicone-rubber pads). The method is an adaptation of existing spectrophotometric procedures based on the sequential coupling reactions with glucose-6-phosphate dehydrogenase and NADP+. The rate of appearance of NADPH fluorescence at 460 nm (excitation wavelength, 340 nm) is monitored and related to the glucose concentration in plasma or serum. The calibration curve is linear to 2.50 g/liter. The chief advantages of this method over the spectrophotometric procedure are low cost and rapid response. The results obtained correlate well with those of the o-toluidine method (correlation coefficient, 0.986).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lipase Production in Solid State Fermentation Using Aspergillus niger: Response Surface Methodology

Among enzymes, lipases have been widely investigated because of the numerous industrial applications. In this study, optimization of lipase production by Aspergillus niger in solid state fermentation from rice bran as solid substrate was investigated. The optimal conditions with the aid of central composite design (CCD) under response surface methodology (RSM) were obtained.  In the analysis of...

متن کامل

Preliminary examination of time-resolved fluorometry for protein array applications.

The advantages of time-resolved fluorometry over conventional fluorometric analysis are well known. However, time-resolved fluorescence has not as yet found wide applications in protein microarray or other multiparametric methods of analysis. Here we describe a general method which is suitable for multiparametric and microarray analysis, based on time-resolved fluorometry. A polystyrene surface...

متن کامل

An Enhanced Viscoplastic Constitutive Model for Semi-Solid Materials to Analyze Shear Localization

Semi-solid materials undergo strain localization and shear band formation as a result of granular nature of semi-solid deformation. In the present study, to analyze the shear localization, a unified viscoplastic constitutive model was developed for the homogeneous flow. Then, a linearized analysis of the stability performed by examining the necessary condition for the perturbation growth. For t...

متن کامل

Substrate Regulated Microaerophily and Chemotaxis by Pseudomonas jessenii strain VT 10 by Raja Mazumder

Low substrate regulated microaerophilic behavior (LSRMB), as measured by changes in microaerophilic band formation in semi-solid medium, was observed in several aerobic bacteria isolated from subsurface soils, Antarctic dry valley soils, an eutrophic pond, a mesophilic pond, an oligotrophic lake and activated sludge. Similar behavior was also exhibited by five Pseudomonas and two Bacillus type ...

متن کامل

A semi-automated fluorometric method for total estrogens in pregnancy urine.

We report a continuous-flow fluorometric method for total urinary estrogens that involves the Kober reaction, with extraction of the reaction product into dichloroethane containing trichloroacetic acid as described by Hahnel and Jones [Clin. Chim. Acta 16, 185 (1967)]. The dichloroethane extraction gives greater stability to the Kober color and sharper separation of aqueous and organic phases. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 21 12  شماره 

صفحات  -

تاریخ انتشار 1975