Simulated response characteristics of Gammasphere
نویسنده
چکیده
The response of the Ge detector array Gammasphere to y-rays, both individually and in cascades, has been modeled with the Monte Carlo code GEANT 3. The effects on the performance of Gammasphere of including an auxiliary detector, the Microball, are investigated. The use of the existing Ge detectors and BGO suppression detectors as a y-ray multiplicity and total y-ray energy spectrometer is explored, and its total energy multiplicity (H, k) response is simulated in detail. The utility of the Hevimet collimators in spectroscopic studies, as opposed to the use of the available (H, k) information, is discussed.
منابع مشابه
How Far From Stability Can We Go Using Gammasphere and the FMA?
This paper presents new results obtained using the U.S. national gamma-ray facility Gammasphere, which has been operating at the ATLAS accelerator at Argonne National Laboratory since January 1998. Gammasphere was built at Lawrence Berkeley Laboratory and used primarily as a powerful spectrometer for studying nuclei at the highest spins [1].
متن کامل‘‘HERCULES’’: Design, instrumentation, and performance characteristics of a high-efficiency evaporation-residue counter under a lot of elastic scattering for spectroscopic studies with Gammasphere
A high-efficiency evaporation-residue counter (named HERCULES) has been designed and constructed. It consists of 64 thin fast-plastic scintillators arranged in four rings covering an angular range of 3.1–19:1 at 30.9 cm from the target. The device design has been optimized for use with GAMMASPHERE. Evaporation residues are well separated from elastic scattering, fission events, and other undesi...
متن کامل“Neutron Shell”: A high efficiency array of neutron detectors for γ−ray spectroscopic studies with Gammasphere
A shell of neutron detectors was designed, constructed, and employed in γ−ray spectroscopy with Gammasphere. It consists of up to 35 tapered regular hexagons that replace the same number of forward Ge-detector modules in Gammasphere. The shell was designed for high detection efficiency and very good neutron−γ discrimination. The simultaneous use of time of flight, and two methods of pulse shape...
متن کاملa Simplified Model of Distributed Parameter Systems
A generalized simplified model for describing the dynamic behavior of distributed parameter systems is proposed. The various specific characteristics of gain and phase angle of distributed parameter systems are investigated from frequency response formulation and complex plane representation of the proposed simplified model. The complex plane investigation renders some important inequality cons...
متن کاملFabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics
Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measu...
متن کامل