Combined Intacs SK and Corneal Collagen Cross-linking for the Treatment of Keratoconus

نویسندگان

  • Ramez Barbara
  • Hanna Garzozi
  • Adel Barbara
چکیده

Purpose: To evaluate the efficacy of the combined treatment of Intacs SK (Severe keratoconus) and corneal collagen crosslinking in the management of advanced keratoconus (KC). Setting: Private laser center, Haifa, Israel. Affiliated to Hadassah Hospital, Jerusalem. Methods: This is a retrospective study. Intacs SK were implanted using manual technique in eyes with moderate-tosevere keratoconus followed by collagen corneal cross-linking (CXL). Evaluation included uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), manifest refraction, slit-lamp examination and corneal topography. Ocular response analyzer (ORA) was used to assess the corneal hysteresis (CH) and the corneal resistance factor (CRF). Results: We report on improvement of the UCVA, BSCVA, decrease in myopia, astigmatism and keratometry readings. No significant change in CRF or CH was noted. Conclusion: The combined treatment of Intacs SK and corneal CXL for the treatment of advanced keratoconus is safe and effective. The combined treatment resulted in improved UCVA, BSCVA, keratometry readings and regularization of the topography but no significant change in CRF and HS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Corneal Aberrometry Parameters Before and After Cross-Linking in Patients with Keratoconus

Background and Objective: In the last decade, cross-linking (CXL) has been widely used for treating people with progressive keratoconus. The present study aimed to compare corneal aberrometry parameters before and after CXL in patients with keratoconus. Materials and Methods: In this cross-sectional study, 67 patients with keratoconus referred to Farshchian Sina Medical Education Center, Hamad...

متن کامل

Polar Value Analysis of Corneal Astigmatism in Intrastromal Corneal Ring Segment Implantation

Purpose. To evaluate surgically induced astigmatism (SIA) and the average corneal power change in symmetric intrastromal corneal ring segment (ICRS) implantation. Methods. The study included 34 eyes of 34 keratoconus patients who underwent symmetric Intacs SK ICRS implantation. The corneal pocket incision meridian was the preoperative steep meridian. Corneal power data were obtained before and ...

متن کامل

Comparative Results in a Combined Procedure of Intrastromal Corneal Rings Implantation and Cross-linking in Patients with Keratoconus: A Retrospective Study

INTRODUCTION Corneal thinning disorders caused by keratoconus often lead to protrusion, irregular astigmatism, and even perforation. Keratoconus, like other corneal ectasia, does not have a known cause. Severe cases of keratoconus may require correction or restoration of tectonic integrity of the cornea by surgical means. Intracorneal ring segments are a new modality in the treatment of corneal...

متن کامل

Corneal melting after collagen cross-linking for keratoconus: a case report

INTRODUCTION Corneal collagen cross-linking is a rather new technique that uses riboflavin and ultraviolet A light for collagen fiber stabilization in keratoconus corneas. Other than reversible side effects, the preliminary results of corneal collagen cross-linking studies suggest that it is a rather safe technique. In this report, we demonstrate a case of corneal melting after corneal collagen...

متن کامل

Refractive and topographic results after exchange of Intacs SK for Ferrara intrastromal corneal ring segments after unsuccessful implantation for keratoconus correction

In the past, the main goal of intrastromal corneal ring segment (ICRS) implantation was to reduce keratometry. Current treatment nomograms based on classifi cation of the ectasia phenotype aim to provide both therapeutic and refractive correction. We present the case of a 39-year-old woman diagnosed in 2011 with keratoconus in both eyes, with low best spectacle-corrected distance visual acuity ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012