Results of three to 10 year follow up of balloon dilatation of the pulmonary valve.
نویسندگان
چکیده
BACKGROUND The results of immediate and short term follow up of balloon dilatation of the pulmonary valve have been well documented, but there is limited information on long term follow up. OBJECTIVE To evaluate the results of three to 10 year follow up of balloon dilatation of the pulmonary valve in children and adolescents. SETTING Tertiary care centre/university hospital. DESIGN Retrospective study. METHODS AND RESULTS 85 patients (aged between 1 day and 20 years, mean (SD) 7.0 (6.4) years) underwent balloon dilatation of the pulmonary valve during an 11 year period ending August 1994. There was a resultant reduction in the peak to peak gradient from 87 (38) to 26 (22) mm Hg. Immediate surgical intervention was not required. Residual gradients of 29 (17) mm Hg were measured by catheterisation (n = 47) and echo Doppler (n = 82) at intermediate term follow up (two years). When individual results were scrutinised, nine of 82 patients had restenosis, defined as a peak gradient of 50 mm Hg or more. Seven of these patients underwent repeat balloon dilatation of the pulmonary valve: peak gradients were reduced from 89 (40) to 38 (20) mm Hg. Clinical evaluation and echo Doppler data of 80 patients showed that residual peak instantaneous Doppler gradients were 17 (15) mm Hg at long term follow up (three to 10 years, median seven), with evidence for late restenosis in one patient (1.3%). Surgical intervention was necessary to relieve fixed infundibular stenosis in three patients and supravalvar pulmonary stenosis in one. Repeat balloon dilatation was performed to relieve restenosis in two patients. Actuarial reintervention free rates at one, two, five, and 10 years were 94%, 89%, 88%, and 84%, respectively. Pulmonary valve regurgitation was noted in 70 of 80 patients at late follow up, but neither right ventricular dilatation nor paradoxical interventricular septal motion developed. CONCLUSIONS The results of late follow up of balloon dilatation of the pulmonary valve are excellent. Repeat balloon dilatation was performed in 11% of patients and surgical intervention for subvalvlar or supravalvar stenosis in 5%. Most patients had mild residual pulmonary regurgitation but right ventricular volume overload was not required. Balloon dilatation is the treatment of choice in the management of moderate to severe stenosis of the pulmonary valve. Further follow up studies should be undertaken to evaluate the significance of residual pulmonary regurgitation.
منابع مشابه
نارسایی دریچه پولمونر پس از ترمیم با بالون در کودکان مبتلا به تنگی این دریچه
Background: Pulmonary valve stenosis (PS) is one of the most common congenital heart disease in children. Isolated pulmonary stenosis is the most common form of pulmonary stenosis. Isolated Pulmonary stenosis is responsible for 8 to 10 percent of congenital heart disease. Balloon valvuloplasty is the choice of treatment for this cardiac disease. One of the most important complications of this d...
متن کاملIntegrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملMain indications and long-term outcomes of reoperation after initial repair of tetralogy of Fallot
Background and Objective: The aim of this study was to analyze our indications, surgical procedures, and clinical outcomes of patients undergoing reoperation after surgical correction of tetralogy of Fallot (TOF). Methods: Thirty seven consecutive patients who underwent reoperation late after intra-cardiac repair of TOF within a period of 10 years were assessed. Results: The most co...
متن کاملIndependent predictors of long-term results after balloon pulmonary valvuloplasty. Valvuloplasty and Angioplasty of Congenital Anomalies (VACA) Registry Investigators.
BACKGROUND This study was performed to determine independent predictors of long-term outcome after percutaneous balloon dilation of congenital pulmonary valve stenosis. Smaller follow-up series of patients after balloon pulmonary valvuloplasty have shown inconsistent results regarding the independent relation between prognostic factors and long-term outcome, as many patient selection and techni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 80 6 شماره
صفحات -
تاریخ انتشار 1998