Comparison Between the Effects of Ringer`s Lactate and Hydroxyethyl Starch on Hemodynamic Parameters After Spinal Anesthesia: A Randomized Clinical Trial
نویسندگان
چکیده
BACKGROUND Hypotension during spinal anesthesia is common and can lead to severe injuries and even death. Administration of crystalloid fluids is advised to prevent occurrence of hypotension; however its effectiveness is still the matter of arguments. OBJECTIVES This study was designed to compare the effects of Ringer`s lactate and hydroxyethyl starch 6% on hemodynamic parameters after spinal anesthesia in patients undergoing orthopedic surgeries on lower limbs. PATIENTS AND METHODS This randomized clinical trial was performed in Rasoul Akram Hospital, Tehran, Iran. 60 patients undergoing elective femoral fracture surgeries with spinal anesthesia were included in this study. Fitted patients were randomly divided into two equal groups. After entrance to the operation room and before spinal anesthesia, patients' hemodynamic parameters including systolic blood pressure (SBP), cardiac output (CO), and cardiac index (CI) were evaluated using monitoring electro-velocimetry set. In both groups, spinal anesthesia was performed using needle no. 25 and 3 mL of marcaine 0.5% in the sterile situation. None of the treatment group was aware of investigated group during the study. RESULTS The baseline values of mentioned variables did not show a significant difference between two groups using t-test (P > 0.05). Also SBP, CI, and CO after intervention was not significantly different between two groups using t-test (P > 0.05). CONCLUSIONS The result of present study on patients undergoing femoral fracture surgeries who received Hetastarch or Ringer`s lactate solutions showed that Hetastarch was not significantly more effective in compensation of hypotension induced by spinal anesthesia.
منابع مشابه
Volume replacement therapy during hip arthroplasty using hydroxyethyl starch (130/0.4) compared to lactated Ringer decreases allogeneic blood transfusion and postoperative infection.
BACKGROUND AND OBJECTIVES Hydroxyethyl starch (HES) 130/0.4 is considered an effective plasma expander when compared to crystalloids. There is controversy around its superiority regarding hemodynamic optimization and about possible detrimental effects on coagulation. The aim of this study was to compare the effects of HES 130/0.4 to lactated Ringer solution during hip arthroplasty in adult pati...
متن کاملThe Effect of Prophylactic Infusion of Combined Ephedrin and Phenylephrine on Maternal Hemodynamic after Spinal Anesthesia for Cesarean Section: A Randomized Clinical Trial
Several techniques have been proposed to prevent hypotension in obstetric patients. Ephedrine and phenylephrine are individually used to prevent maternal hypotension; however, each has its own drawbacks. Some researchers have reported that the infusion of combined ephedrine and phenylephrine immediately after spinal anesthesia for cesarean delivery reduces the incidence of maternal hypotension....
متن کاملComparison of the Effects of Pre-Anesthetic Administration of Normal Saline, Ringer and Voluven on the Spread of Sensory Block With Hyperbaric Bupivacaine Spinal Anesthesia
BACKGROUND Spinal anesthesia is an important and commonly used method for surgical anesthetic in operating rooms. However, even with identical drug dosage and administration mode, the extent of drug distribution in vivo is highly variable and difficult to control. Preanesthetic administration of fluids immediately before spinal anesthesia (preload) is normal practice. The choice of fluid type m...
متن کاملComparing Different Epinephrine Concentrations for Spinal Anesthesia in Cesarean Section: A Double-Blind Randomized Clinical Trial
Background: Although various anesthetic techniques can be used in different kinds of surgeries, spinal anesthesia has received considerable attention for the lower abdomen and lower extremities surgeries and cesarean section. This study aimed at comparing the effect of adding epinephrine 1:1000 and 1:10000 to lidocaine and fentanyl in spinal anesthesia on the prolongation of paralysis, analgesi...
متن کاملمقایسه اثر هیدروکسی اتیل استارچ با کریستالوئیدها بر تغییرات همودینامیک
Aims and Background: Although controversial, many studies have shown effectiveness of colloid loading as a substitute for crystalloids on reducing the incidence of hypotension in spinal anesthesia. This study was conducted to compare the effects of three intravenous fluid regimens on hemodynamic changes following spinal anesthesia in cesarean section. The regimens included 6% Hydroxy ethyl star...
متن کامل