Constant vs auto-continuous positive airway pressure in patients with sleep apnea hypopnea syndrome and a high variability in pressure requirement.

نویسندگان

  • André Noseda
  • Chantal Kempenaers
  • Myriam Kerkhofs
  • Stéphanie Braun
  • Paul Linkowski
  • Ernest Jann
چکیده

STUDY OBJECTIVES Auto-continuous positive airway pressure (CPAP) has been reported to have no more efficacy than constant CPAP in unselected patients with sleep apnea hypopnea syndrome (SAHS). The aim of this study was to evaluate patients judged to be good candidates for auto-CPAP because of a high within-night variability in pressure requirement. DESIGN Single-blind, randomized, cross-over study (2 x 8 weeks) to compare auto-CPAP with constant CPAP. PATIENTS Outpatients with moderate-to-severe SAHS attending the chest clinic. INTERVENTIONS Patients were equipped at home in the auto-CPAP mode (model GK418A; Malinckrodt; Nancy, France), using a 4- to 14-cm H(2)O pressure range. Those individuals having a high within-night variability in pressure requirement, assessed at the end of a 14-day run-in period, were included in the cross-over study. Auto-CPAP was compared with constant CPAP (according to a titration night in the sleep laboratory) in terms of compliance, efficacy on apneas (assessed from the pressure monitor), and sleepiness (assessed on the Epworth sleepiness scale). MEASUREMENTS AND RESULTS Of 90 consecutive patients with SAHS, 27 patients were selected for a within-night variability in pressure requirement exceeding a given threshold. After completion of the cross-over, 24 patients were evaluable. The median percentage of nights the machine was used was 95.5% (range, 45 to 100%) on constant CPAP, and 96.5% (range, 40 to 100%) on auto-CPAP; the median apnea index recorded by the device was 0.40/h (range, 0 to 2.40/h) on constant CPAP, and 0.45/h (range, 0 to 5.80/h) on auto-CPAP (differences not significant). The mean Epworth sleepiness score was significantly (p < 0.01) lower on auto-CPAP (5.1; SD, 2.8) than on constant CPAP (6.1; SD, 2.8). CONCLUSIONS In patients selected for a high within-night variability in pressure requirement, auto-CPAP administered via a GK418A device was equivalent to constant CPAP based on a titration night in the sleep laboratory. Subjective ratings for sleepiness were slightly lower on auto-CPAP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Constant vs. automatic continuous positive airway pressure therapy: home evaluation.

STUDY OBJECTIVES To compare the efficacy and patient tolerance, compliance, and preference between auto-continuous positive airway pressure (CPAP) and constant CPAP. DESIGN Single-blinded, crossover, cohort study of consecutive patients with obstructive sleep apnea syndrome, with two treatment periods of 2 months each. PATIENTS Twenty-five patients (22 men, 3 women) with sleep apnea syndrom...

متن کامل

Efficacy and cost of home-initiated auto-nCPAP versus conventional nCPAP.

STUDY OBJECTIVES To compare in a multicenter prospective study the efficacy and cost of conventional nasal continuous positive airway pressure (nCPAP) initiated at the sleep laboratory versus auto-nCPAP initiated at home. DESIGN Patients with severe obstructive sleep apnea syndrome (OSAS) were randomized to treatment with either the REM+ auto device in constant mode at the effective pressure ...

متن کامل

Complex sleep apnea syndrome: is it a unique clinical syndrome?

STUDY OBJECTIVES Some patients with apparent obstructive sleep apnea hypopnea syndrome (OSAHS) have elimination of obstructive events but emergence of problematic central apneas or Cheyne-Stokes breathing pattern. Patients with this sleep-disordered breathing problem, which for the sake of study we call the "complex sleep apnea syndrome," are not well characterized. We sought to determine the p...

متن کامل

Obstructive Sleep Apnea in Ischemic Stroke patients

OBJECTIVE To investigate the prevalence of obstructive sleep apnea in patients with ischemic stroke and to evaluate the effectiveness of nasal continuous positive airway pressure treatment. METHODS Overnight polysomnography was performed by a computerized system in 19 subjects with ischemic stroke. Patients with an apnea-hypopnea index > or = 5 were considered to have obstructive sleep apnea....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 126 1  شماره 

صفحات  -

تاریخ انتشار 2004