Preparation, radiochemical purity control and stability of 99mTc-mertiatide (Mag-3).

نویسندگان

  • Formijn J van Hemert
  • Henk van Lenthe
  • Kirsten J M Schimmel
  • Berthe L F van Eck-Smit
چکیده

BACKGROUND Scintigraphic image analysis of 99mTc-mertiatide (Mag-3, mercaptoacetyltriglycine) clearance provides the determination of the blood flow, the tubular transit time and the excretion as well from both kidneys. Radiopharmaceutical routine recommends a radiochemical purity control before administration of the product to a patient. The main objective of this study is to develop a Mag-3 labeling procedure that fits better than the previous one in our daily routine production of radiopharmaceuticals. METHODS Increasing proportions of 99mTc-Mag-3 were measured during the heating and cooling steps of the Mag-3 labeling procedure. HPLC analysis was used to confirm the results of a rapid radiochemical quality control assay on standard ITLC-SG paper. RESULTS The reconstitution time takes 20-25 minutes from the harvest of pertechnetate to a ready-for-use calibrated patient syringe. The HPLC profile of 99mTc-Mag-3 including its minor impurities remains unchanged for 24-48 hours after reconstitution. CONCLUSIONS The application of a programmable Peltier-directed device for heating/cooling provides a better control of the temperature course. The procedure proposed fully meets the labeling criteria recommended by the supplier and can be performed with a minimum of attention within a time-span that we formerly needed for solely the radiochemical purity control assay. Moreover, 99mTc-Mag-3 prepared in this way seems to be considerably more stable than mentioned in the manufacturer's instructions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of solvent flow rate in mini-column testing of 99mTc-mertiatide.

OBJECTIVE The recommended method for radiochemical purity testing of 99mTc-mertiatide involves the use of a C-18 solid-phase mini-column cartridge. The mertiatide package insert states that the solvents should be "pushed through the cartridge slowly," but a flow rate is not specified. The mini-column cartridge instruction sheet recommends flow rates of 5-10 and 2-10 mL/min for conditioning and ...

متن کامل

Technetium-99m radiopharmaceutical preparation problems: 12 years of experience.

OBJECTIVE Chemical reactions involved in preparing 99mTc radiopharmaceuticals occasionally result in products of substandard purity. A retrospective examination of preparation problems that occurred in the author's institution was conducted to better define the incidence, recognize patterns and identify causes of substandard 99mTc radiopharmaceutical products. METHODS All 99mTc radiopharmaceu...

متن کامل

Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals.

The influence of effective room temperature on the radiochemical purity of 99mTc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99mTc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the wo...

متن کامل

A new two-strip TLC method for the quality control of technetium-99m mercaptoacetyl-triglycine (99mTc-MAG3)

Background 99mTc-mercaptoacetyl-triglycine (99mTc-MAG3) has been used for dynamic renal imaging since about 30 years. Free pertechnetate (99mTcO4), colloidal 99mTc ((99mTcO2)n), 99mTc-tartrate (precursor), precomplexes (99mTc-(MAG3)x) and lipophilic 99mTc-MAG2 are the main radiochemical impurities that may occur in the preparation. The total amount of these impurities has to be identified befor...

متن کامل

Freeze-dried cold kit for preparation of 99mtc-ciprofloxacin as an infection imaging agent

  Introduction: Radiolabeled antibiotics are being used for the specific diagnosis of infection by exploiting their specific binding properties to the bacterial components, thereby making it possible to differentiate infection from sterile lesions. The aim of this work was to prepare and evaluate a freeze-dried kit of ciprofloxacin designed for the labeling with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2005