First evaluation of the WASP, a new automated microbiology plating instrument.

نویسندگان

  • Paul P Bourbeau
  • Brandi Lynn Swartz
چکیده

Many laboratories are experiencing growing shortages of trained microbiology technologists and technicians. Consequently, there is considerable interest in new automation that could potentially lessen labor demands for specimen processing. In this study, we present the first published evaluation of a new microbiology instrument, the Walk Away Specimen Processor (WASP), manufactured by Copan, Inc., in which we evaluated cross-contamination, the accuracy of plating, and the quality of the results. The absence of cross-contamination was demonstrated by plating a total of 200 alternating inoculated and sterile specimen tubes. The ability of the WASP to subculture enrichment broths was evaluated with 106 Lim broth specimens, with the results being identical to those obtained by testing by routine methods. Plating of urine specimens with the WASP was compared to plating with the Dynacon Inoculab instrument. Three hundred specimens were plated in duplicate on both instruments with 1-microl loops, and 293 specimens were plated in duplicate on both instruments with 10-microl loops. The results of duplicate plating with the same instrument (replicate plating) and of the consensus agreement between the two instruments were compared. The replicate plating results were comparable for both instruments, while the WASP had more specimens with significant results than the Inoculab with the 1-microl loop only. Lastly, for the plating of 113 specimens in ESwab tubes, the manual method and WASP plating each yielded 90 potential pathogens. In summary, we report the first evaluation of a new microbiology specimen-plating instrument, the WASP, which offers opportunities for the automated plating of microbiology specimens to an extent that has not been possible to date.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Inoculation of Urine Samples with the Copan WASP and BD Kiestra InoqulA Instruments

This study evaluated the quantitative results from and quality of the inoculation patterns of urine specimens produced by two automated instruments, the Copan WASP and the BD InoqulA. Five hundred twenty-six urine samples submitted in 10-ml canisters containing boric acid were processed within 30 min on an InoqulA instrument plating 10 μl of specimen, and on two WASP instruments, one plating 1 ...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Clinical evaluation of the walk-away specimen processor and ESwab for recovery of Streptococcus agalactiae isolates in prenatal screening specimens.

Rectal/vaginal specimens (n = 97) were collected in parallel using ESwab and Liquid Stuart (LS) rayon fiber wrapped swab collection devices. Each collection device was used to directly inoculate culture medium and LIM broth. Medium inoculation by ESwab was conducted using the Walk-Away specimen processor (WASP). Medium inoculation by the LS device was conducted manually. The sensitivities of ES...

متن کامل

Evaluation of optimal waste management in the plating industry based on the Delphi Method and Fuzzy Analytic Hierarchy Process (Case Study: Paitakht Industrial District of Tehran)

The plating industry is one of the main toxic chemicals consumers, which uses various chemicals, including solvents, acids, bases, cleansers, sophisticated organic ingredients, and metal salts of cadmium, nickel and chromium. Due to the growing production of industrial waste in spite of actions related to these wastes’ management, no comprehensive pattern was introduced at different levels. Thi...

متن کامل

Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation.

The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial speci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 47 4  شماره 

صفحات  -

تاریخ انتشار 2009