Effect of cricoid pressure on insertion of and ventilation through the cuffed oropharyngeal airway.

نویسندگان

  • R M Dravid
  • P Reed
  • M Stoneham
  • M T Popat
چکیده

We have assessed the effect of cricoid pressure on insertion of and ventilation through the cuffed oropharyngeal airway (COPA) in 53 patients, in a double-blind, randomized study. Two anaesthetists assessed adequacy of ventilation in anaesthetized and paralysed patients at the same time but using different methods. The first assessed ventilation clinically, by observing synchronized chest expansion with gentle manual ventilation and the second noted measurements of tidal volume (VT) and peak inspiratory pressure (PIP). Five mask ventilated breaths ('baseline') were assessed as above. Patients were then allocated randomly to receive cricoid pressure (group A, n = 28) or no cricoid pressure (group B, n = 25). Five further mask ventilated breaths ('after manoeuvre') were again assessed. A COPA was then inserted and five further breaths ('after COPA') were assessed. A COPA was inserted at the first attempt in all patients except for one in group A who required two attempts. COPA placement was difficult in one patient in group B who had a small distance between the incisor teeth. Ventilation was clinically 'adequate' in all patients except for one in the cricoid pressure group. There were no significant differences in measured VT or PIP between 'baseline' and 'after manoeuvre' breaths. Significant differences in VT and PIP were found after COPA insertion in the group that received cricoid pressure, with a mean decrease in VT of 108 ml (P = 0.0049) and a mean increase in PIP of 5.2 cm H2O (P = 0.0111).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Cricoid pressure prevents placement of the laryngeal tube and laryngeal tube-suction II.

BACKGROUND The laryngeal tube has a potential role in patients with a difficult airway, but cricoid pressure is required if the patient is at risk of aspiration. The effect of cricoid pressure on insertion of these devices is unknown. METHODS In a randomized cross-over study, the laryngeal tube (25 patients) or the laryngeal tube-suction II (15 patients) was inserted with cricoid pressure app...

متن کامل

Haemodynamic and electroencephalographic response to insertion of a cuffed oropharyngeal airway: comparison with the laryngeal mask airway.

We have compared the cuffed oropharyngeal airway (COPA), a modified Guedel airway device with a specially designed cuff at its distal end, with the laryngeal mask airway (LMA), on haemodynamic and electroencephalographic (EEG) responses to insertion. In addition, we examined the haemodynamic and EEG changes during initiation of the effect-compartment controlled infusion. We studied 35 female pa...

متن کامل

Cricoid pressure impedes positioning and ventilation through the laryngeal mask airway.

PURPOSE To assess the effect of cricoid pressure on the positioning of and ventilation through the laryngeal mask airway (LMA). METHODS In a double-blind, randomized design, the LMA was inserted with (CP[+] group, n = 20) or without double-handed cricoid pressure (CP[-] group, n = 20). Ventilation through the LMA was assessed by measuring expiratory tidal volume and judged as adequate when a ...

متن کامل

Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 84 3  شماره 

صفحات  -

تاریخ انتشار 2000