Validating MRI Field Homogeneity Correction Using Image
نویسندگان
چکیده
For image analysis techniques to be of utility in medical diagnosis systems it is necessary to be able to perform quality control over the results they produce. Input data must conform to the assumptions within the algorithm if useful results are to be achieved. Automation of this process is essential if vision algorithms are to form components in analysis systems. In this paper we present a technique to validate the correction of field inhomogeneity in MR images. The initial intention was to use information measures to check the improvement due to correction. However, it will be shown that the standard log entropy calculation for information measurement does not have the required properties, specifically grey-level scale invariance. We present an alternative, scaleinvariant information measure derived using conventional likelihood approaches, that can be applied as an absolute measure of information content. We show this technique in use for the validation of our existing coil correction method [9].
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملValidating MRI Field Homogeneity Correction Using Image Information Measures
For image analysis techniques to be of utility in medical diagnosis systems it is necessary to be able to perform quality control over the results they produce. Input data must conform to the assumptions within the algorithm if useful results are to be achieved. Automation of this process is essential if vision algorithms are to form components in analysis systems. In this paper we present a te...
متن کاملCorrection of Intensity In-Homogeneity of MR Image Based on Average Median Intensity Value Method
The Magnetic Resonance Image (MRI) may be valuable techniques for learning the structural property of the human brain. However, the reproducibility of imaging results, that arises from swish intensity variation happens the entirety MR image, named as Intensity in-homogeneity or nonuniformity. The intensity in-homogeneity may be a hurdles encountered in human and computer interpretations and ana...
متن کاملQuantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation
Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...
متن کاملNew Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor
Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...
متن کامل