Effect of Non-Rectangular Spectra on Receiver Sensitivity

ثبت نشده
چکیده

So far the receiver performance analysis assumed ideal rectangular spectra for all of the filters in our system. This chapter analyzes the effect of non-rectangular filter shapes on the receiver sensitivity. Unlike the case of the rectangular spectra analyzed in Chapter 2, the channel seen by the signal and the noise is different now. While the signal path contains two optical filters, one used to spectrum-slice at the transmitter and another used at the receiver to reject out-of-band ASE noise in the preamplifier and also to select the appropriate WDM channel, the noise path contains only one filter due to the fact that the main source of noise is the optical preamplifier. The method used to analyze the effect of non-rectangular spectra on the receiver sensitivity is similar to that used by Arya in [7]. There is however, one significant difference; while Arya made the assumption that when the data signal and noise are added the resulting signal could also be approximated as being chi-square distributed, we did not make such an assumption. Even though the noise and the data signal each have a chi-square distribution, the sum will not be chisquare distributed. This distribution is not needed when applying the Saddlepoint Approximation which only requires the MGF of the received signal to evaluate the receiver’s performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Effect of Interchannel Interference on Receiver Performance

In the previous two chapters we have assumed our systems to be ideal without any interchannel interference. In this chapter we analyze the effects of interchannel interference on the performance of the receiver. The model assumed is that of rectangular spectra with spacing of channels less than channel width so that there is some overlap. It is shown that some overlap in the system is acceptabl...

متن کامل

Effect of Non-ideal Boundary Conditions on Buckling of Rectangular Functionally Graded Plates

We have solved the governing equations for the buckling of rectangular functionally graded plates which one of its edges has small non-zero deflection and moment. For the case that the material properties obey a power law in the thickness direction, an analytical solution is obtained using the perturbation series. The applied in-plane load is assumed to be perpendicular to the edge which has no...

متن کامل