Fixation of an Anatomically Designed Cementless Stem in Total Hip Arthroplasty
نویسندگان
چکیده
Purpose. The Anatomic Fiber Metal plus stem (Zimmer) is one of the anatomically designed cementless stems to achieve stable fixation by metaphyseal fit. We studied outcomes of cementless total hip arthroplasty using this stem and possible effects of metaphyseal fit on outcomes. Methods. The cementless total hip arthroplasty using this stem was performed for 155 hips. One hundred and thirty-seven hips of 122 patients were followed for 5 to 16 (mean, 9.7) years and entered into the study. The metaphyseal fit was defined as good or poor in an anteroposterior radiograph after surgery. We studied the fixation of the stem and bone reaction on an anteroposterior radiograph at the final followup. Results. Twelve hips had revision, six acetabular components and six acetabular liners. No stem was revised. The biological fixation of the stem was bone ingrown fixation for 136 hips and unstable for one. The metaphyseal fit was good for 83 hips and poor for 54 hips. There were no differences for stem fixation and bone reaction between the two groups. Conclusions. The fixation of the stem was stable at a mean followup of 9.7 years independently from metaphyseal fit.
منابع مشابه
Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملCementless Femoral Fixation in Total Hip Arthroplasty
In 1995, the NIH (National Institutes of Health) Consensus Development Panel on Total Hip Replacement supported the use of hybrid fixation with a cemented stem and a noncemented cup because of excellent long-term results. However, today, 60% to 90% of the approximately 200,000 total hip arthroplasties performed yearly in the United States involve both a cementless cup and a cementless stem. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012