Mobile echoes on prosthetic valves are not reproducible. Results and clinical implications of a multicentre study.
نویسندگان
چکیده
AIMS To test the hypothesis that inter-observer variability accounts for the wide variation in reported prevalences of fibrin strands on prosthetic heart valves and to develop criteria for their identification and reporting. METHODS AND RESULTS A videotape with 30 sequences of prosthetic heart valves imaged by transoesophageal echocardiography and showing abnormalities such as strands, microbubbles, and spontaneous echocardiographic contrast, was assessed in 13 European and three American centres. There were three duplicated examples, unbeknown to the observers. Definitions and reported prevalence rates of the abnormalities were analysed, and inter- and intra-observer agreement estimated with the kappa statistic. Mobile echoes were identified in 40 to 80% of the sequences on the tape. The reported prevalence of mobile echoes correlated with the time spent reporting the tape. There was moderate inter-observer agreement for the identification of any mobile echoes (kappa = 0.38), but no agreement for their labelling (kappa = 0.22), in spite of similar definitions. Intra-observer reproducibility was good (agreement in 76% of the reduplicated sequences). CONCLUSIONS The true prevalence and potential significance of mobile echoes on prosthetic heart valves cannot be assessed unless inter-observer consensus on echocardiographic criteria for identifying such echoes is reached.
منابع مشابه
Echocardiographic determination of mitral disc valve excursion.
Disc excursion and opening and closing velocities of prosthetic disc valves can be measured accurately by diagnostic echocardiography. The ultrasound beam is projected along the longitudinal axis of the valve and the echoes arising from the struts, disc, and suture ring are displayed on the oscilloscope. Twenty-four patients with normally functioning mitral Beall valves of various sizes and thr...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملIntegrated CT ad MR imaging in alcohol-related isolated left ventricular fatty infiltration.
ment? J Am Soc Echocardiograph 2009;8:895–8. 12. Ionescu AA, Moreno de la Santa P, Dunstan FD, Butchart EG, Fraser AG. Mobile echoes on prosthetic valves are not reproducible. Eur Heart J 1999;20: 140–7. 13. Kiavar M, Sadeghpour A, Bakhshandeh H, Bassiri HA, Tayyebi P, Esmaeilzadeh M et al. Are prosthetic valve fibrin strands negligible? The associations and significance. J Am Soc Echocardiogr ...
متن کاملPregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملProsthetic valve strands.
A 62-year-old woman presented with a sudden transient ischemic attack (TIA). Symptoms resolved within 2 hours of onset. Neurological evaluation and workout for etiology of the TIA was unremarkable. Her medical history included having a St. Jude mitral valve replacement for mitral regurgitation 10 years before presentation. The patient had been maintained on warfarin with INR levels generally in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 20 2 شماره
صفحات -
تاریخ انتشار 1999