Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse.

نویسندگان

  • Mauro Pepi
  • Gloria Tamborini
  • Anna Maltagliati
  • Claudia Agnese Galli
  • Erminio Sisillo
  • Luca Salvi
  • Moreno Naliato
  • Massimo Porqueddu
  • Alessandro Parolari
  • Marco Zanobini
  • Francesco Alamanni
چکیده

OBJECTIVES The aim of this study, undertaken in patients who underwent mitral valve (MV) repair surgery, was to evaluate the feasibility and accuracy of 3-dimensional (3D) transthoracic (TTE) and transesophageal (TEE) echocardiography in the evaluation of MV pathology. BACKGROUND A pre-operative assessment of MV anatomy is essential to surgical design in patients undergoing MV repair. Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy, 3D TTE and 3D TEE could increase the understanding of MV apparatus and individual scallop identification. METHODS One-hundred-twelve consecutive patients with severe mitral regurgitation due to MV prolapse underwent a complete 2D and 3D TTE the day before surgery and a complete 2D and 3D TEE in the operating room. Echocardiographic data obtained by the different techniques were compared with surgical inspection. RESULTS Three-dimensional techniques were feasible in a relatively short time (3D TTE: 7 +/- 4 min; 3D TEE: 8 +/- 3 min), with good (3D TTE 55%; 3D TEE 35%) and optimal (3D TTE 21%; 3D TEE 45%) imaging quality in the majority of cases. Three-dimensional TEE allowed more accurate identification (95.6% accuracy) of all MV lesions in comparison with other techniques. Three-dimensional TTE and 2D TEE had similar accuracies (90% and 87%, respectively), whereas the accuracy of 2D TTE (77%) was significantly lower. CONCLUSIONS Three-dimensional TTE and TEE are feasible and useful methods in identifying the location of MV prolapse. They were superior in the description of pathology in comparison with the corresponding 2D techniques and should be regarded as an important adjunct to standard 2D examinations in decisions regarding MV repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

دریچه میترال دو دهانه با تنگی شدید، یک مورد نادر

Double orifice mitral valve (DOMV) is an uncommon anomaly that was first described by Greenfield. Since then more than 200 cases have been reported. In this anomaly, mitral valve has a single fibrous annulus which opens with two openings into the left ventricle. We report a case of DOMV accompanied with severe stenosis in a 22-year old female who had complaints of moderate dyspnea. In transth...

متن کامل

Transesophageal two-dimensional echocardiography in young patients with cerebral ischemic events.

Using transesophageal echocardiography, cardiac structures can be imaged with high resolution. The aim of our study was to evaluate whether transesophageal echocardiography is superior in detecting mitral valve prolapse and other cardiac abnormalities compared with transthoracic echocardiography in an age-matched control group and in young patients with cerebral ischemic events (patient group)....

متن کامل

Clinical and Electrocardiographic comparison of patients with primary Mitral Valve Prolapse Syndrome and control group

ABSTRACT: Mitral Valve Prolapse (WVP) in one of the commonest cardiac abnormalities. Echocardiography has generally been accepted as the diagnostic modality of choice, To assess the characteristic symptoms signs and electrocardiographic abnormalities of MVP results of prospective 500 age and sex matched healthy subjects without echocardiographic MVP (control subjects). The diagnostic criteria...

متن کامل

Utility of real‐time three‐dimensional echocardiography in improved assessment of a mitral valve papillary fibroelastoma

Primary cardiac tumors are exceedingly rare. They are usually first identified by transthoracic echocardiography. However, transesophageal echocardiography (TEE), with the aid of real-time three-dimensional (3D) imaging, can provide additional important mass characteristics. We present a case that demonstrates the usefulness of 3D TEE in characterizing a papillary fibroelastoma.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 48 12  شماره 

صفحات  -

تاریخ انتشار 2006