Filter quality of electret masks in filtering 14.6–594 nm aerosol particles: Effects of five decontamination methods

نویسندگان

  • Tzu-Hsien Lin
  • Chih-Chieh Chen
  • Sheng-Hsiu Huang
  • Chung-Wen Kuo
  • Chane-Yu Lai
  • Wen-Yinn Lin
چکیده

This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks-N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6-594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1-0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of 3-Layer Felt Masks Containing Polypropylene Membranes in Particle Filtration with SARS-CoV-2 Size Range

Background and Aim: The use of a mask is an effective measure to reduce the transmission of Covid-19. Today, due to the lack of N95 masks and medical masks with good performance, felt masks are widely used due to their ease of manufacture and low cost. The aim of this study was to determine the effectiveness of 3-layer felt masks containing polypropylene membranes in filtering particle size in ...

متن کامل

Evaluation of five decontamination methods for filtering facepiece respirators.

Concerns have been raised regarding the availability of National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One possible strategy to mitigate a respirator shortage is to reuse FFRs following a biological decontamination process to render infectious material on the FFR inactive. However, little data exis...

متن کامل

Comparison of nanoparticle filtration performance of NIOSH-approved and CE-marked particulate filtering facepiece respirators.

The National Institute for Occupational Safety and Health (NIOSH) and European Norms (ENs) employ different test protocols for evaluation of air-purifying particulate respirators commonly referred to as filtering facepiece respirators (FFR). The relative performance of the NIOSH-approved and EN-certified 'Conformité Européen' (CE)-marked FFR is not well studied. NIOSH requires a minimum of 95 a...

متن کامل

Effectiveness of three decontamination treatments against influenza virus applied to filtering facepiece respirators.

Filtering facepiece respirators (FFRs) are recommended for use as precautions against airborne pathogenic microorganisms; however, during pandemics demand for FFRs may far exceed availability. Reuse of FFRs following decontamination has been proposed but few reported studies have addressed the feasibility. Concerns regarding biocidal efficacy, respirator performance post decontamination, decont...

متن کامل

کارایی جمع‌آوری فیلتر اولپا در ربایش نانو ذرات آئروسلی

  Background and aims : With the increasing application of nanotechnology concerns about the negative effects of human exposure and environmental releases of these particles is also doubled. Among the most well-known media, ULPA filters are used to control nanoparticles. In this study, the efficiency and pressure drop of ULPA fiber bed for collection and removal of nanoparticles were investigat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017