Determination of percent hemoglobin A1c using a potentiometric method.

نویسندگان

  • Hong Liu
  • Richard M Crooks
چکیده

We report a potentiometric method for measuring the hemoglobin A1c (HbA1c, glycated hemoglobin) concentration, hemoglobin (Hb) concentration, and percent HbA1c (%HbA1c) in human blood hemolysate. The %HbA1c is important for diagnosis and management of diabetes mellitus. Alizarin red s (ARS) is used as a redox indicator. Phenylboronic acid (PBA) binds to both ARS and HbA1c via diol-boronic acid complexation. The binding of PBA to ARS shifts its redox potential negatively. However, when HbA1c competes with ARS for PBA binding, the solution potential shifts positively. This shift is linked to the HbA1c concentration. The concentration of Hb is determined by allowing it to react with Fe(CN)(6)(3-). The potential shift arising from the reduction of Fe(CN)(6)(3-) by Hb is proportional to the logarithm of the Hb concentration. The results obtained for %HbA1c in human blood hemolysate are in good agreement with those determined using a reference method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of costs of hemoglobin A1c determination by point-of-care testing (POCT) and standard hemoglobin A1c analyzer

OBJECTIVE The use of the levels of hemoglobin A1c for the monitoring of glycemic control in patients with diabetes mellitus (DM) is an accepted method of clinical usefulness. A study was performed to assess the relative costs of hemoglobin A1c determination by diagnostic testing at or near the site of patient care (point-of-care testing, POCT) and using the standard hemoglobin A1c analyzer. MET...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 2013