چکیده
H2O as a PET-tracer offers the opportunity to examine perfusion of blood into tissue non-invasively (cf. [1]). It features a short radioactive half-life (≈ 2 min.) and therefore adds a smaller radiation exposure to the patient in comparison to other tracers. The disadvantages arising from the short radioactive half-life are noisy, low-resolution reconstructions. Previous algorithms first reconstruct images from each dynamic H2O dataset independently, e.g. via the standard EM-algorithm (cf. [2]) or FBP. Hence, temporal correlation is neglected. The myocardial blood flow (MBF) and other important parameters, like tissue fraction, arterial and venous spillover effects are computed subsequently from these reconstructed images. Our new method interprets the direct computation of parameters as a nonlinear inverse problem. This implies the need for inversion of a nonlinear operator G(p) (with p denoting the parameters to compute), but allows to skip the process of generating noisy images. The process is schematically described in Figure 1. Therefore, our method takes into account the temporal correlation between the datasets, and not the correlation between noisy, low resolution images. The problem is transferred to a nonlinear parameter identification problem. Furthermore, regularization can be added to each parameter independently, assuring meaningful results.
منابع مشابه
A Nonlinear Variational Method for Improved Quantification of Myocardial Blood Flow Using Dynamic H 2 15 O PET
We provide a new algorithm to quantify myocardial blood flow (MBF) from H2O PET data. The new algorithm differs from existing algorithms by taking into account the temporal correlation of the data sets. H2O as a PET-tracer offers the opportunity to examine perfusion of blood into tissue non-invasively. It features a short half-time (≈ 2 min.) and therefore adds a smaller radiation burden to the...
متن کاملEffect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...
متن کاملBASIC SCIENCE INVESTIGATIONS Absolute Quantification of Myocardial Blood Flow with H2O and 3-Dimensional PET: An Experimental Validation
The purpose of this study was to assess a 3-dimensional (3D)– only PET scanner (ECAT EXACT3D) for its use in the absolute quantification of myocardial blood flow (MBF) using H2O. Methods: Nine large white pigs were scanned with H2O and C15O before and after partially occluding the circumflex (n 4) or the left anterior descending (n 5) coronary artery at rest and during hyperemia induced by intr...
متن کاملGeneration of Parametric Image of Regional Myocardial Blood Flow Using H2O Dynamic PET and a Linear Least-Squares Method
Although a parametric image of myocardial blood flow (MBF) can be obtained from H2O PET using factor and cluster analysis, this approach is limited when factor analysis fails to extract each cardiac component. In this study, a linear least-squares (LLS) method for estimating MBF and generating a MBF parametric image was developed to overcome this limitation. The computer simulation was performe...
متن کاملQuantification of regional myocardial blood flow in vivo with H215O.
Using H215O (half-life = 2.1 min) we demonstrated that a modification of the tissue autoradiographic approach permitted quantitation of myocardial blood flow in open-chest dogs by direct assay of myocardial tissue and that noninvasive estimation with positron-emission tomography (PET) delineated relative myocardial blood flow in intact dogs. In open-chest anesthetized dogs, the single-pass extr...