Electromagnetic Modeling and Sensitivity-Based Optimization of Medical Devices

نویسنده

  • Oskar Talcoth
چکیده

Electromagnetics is a fundamental part of biomedical engineering and modern healthcare due to the electromagnetic nature of several important processes in the human body and the interactions of electromagnetic fields with the human body. As a consequence, electromagnetics is exploited for diagnostic and therapeutic purposes by a multitude of medical devices. The biomedical engineering society strives to develop and design new methods, as well as, to improve existing methods for diagnosis and therapy. In addition, electromagnetic compatibility of both electromagnetic and non-electromagnetic medical devices must be assessed. These tasks can be complicated since electromagnetic measurements in the human body can be difficult and in some cases harmful to the patient. Furthermore, the human body is highly heterogeneous, which makes predictions of its interaction with electromagnetic fields demanding. In this thesis, these problems are mitigated by means of accurate, unbiased, and automatized electromagnetic modeling that feature a number of disciplines: (i) detailed electromagnetic modeling based on Maxwell’s equations; (ii) mathematics with particular emphasis on numerical analysis and optimization; and (iii) large-scale parallel computations on computer clusters. Progress in these three areas enables larger and more difficult problems to be addressed. In particular, this methodology is applied to three biomedical problems in this thesis. First, the electromagnetics of pacemaker lead heating in MRI is modeled with emphasis on the multi-scale characteristic of the problem. The results show the resonant nature of the problem and that detailed modeling is essential to accurately describe this phenomenon. Second, a method for optimization of sensor positions in magnetic tracking systems is proposed. The method uses powerful mathematics to alleviate the difficulties and computational burden associated with experimental or computational trial-anderror procedures. Third, the estimation procedure in EEG-based source localization is facilitated by exploiting electromagnetic reciprocity during the modeling. This reduces the demands for tailored estimation procedures and removes one obstacle for real-time source localization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Analysis of Approximation Methods in Electromagnetic Design

Design optimization of complex electromagnetic devices such as antennas with volumetric material and conductor variations require high computational resources. This burden can be reduced by introducing cost-effective surrogate models into the design optimization framework. Here we present a comparative analysis of various surrogate modeling techniques for material design studies of electromagne...

متن کامل

Antibacterial Susceptibility Pattern of the Pseudomonas aeruginosa and Staphylococcus aureus after Exposure to Electromagnetic Waves Emitted from Mobile Phone Simulator

Background: The increasing use of telecommunication devices such as Wi-Fi modems and mobile phones in the recent years can change the cellular structure of microorganisms so the generation of electromagnetic waves has led to concern in the community whenever be exposed to these fields and may have harmful effects on human health.Material and Methods: Standard strains of bacteria were prepared o...

متن کامل

Multi-objective Measurement Devices Allocation Using State Estimation in Distribution System

Allocation of measurement devices is a necessity of distribution system which is an application of state estimation. In this paper, the problem of active and reactive measurement devices is modeling using a multi-objective method. The objectives of the problem are to minimize the use of measurement devices, increase in state estimation output, improve the state estimation quality and reduce cos...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Modeling a Smart Hospital Information Architecture Based on Internet of Things and Recommender Agent

Introduction: Today, healthcare organizations worldwide are aware of the significance of technology and its impact on the quality of care. Hospitals are one of the most crucial systems in which the utilization of information is particularly important for several reasons. Using discrete-event simulation and developing a recommender agent, this study aimed to allocate IoT devices to patients in s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013