A Method for the Design of UFLS Scheme with Dynamic Correction
نویسندگان
چکیده
This paper presents an adaptive Under Frequency Load Shedding scheme based on Wide Area Measurement System. Due to the lack of enough adaptability to the operation state of the system, the traditional successive approximation under frequency load shedding method will cause excessive cut or undercut problems inevitably. This method consists first in a comprehensive weight index including load characteristics and inertias of generators. Then active-power deficit calculation based on the Low-order Frequency Response Model, concerning the effect of voltage was put forward. Finally, a dynamic correction of the load shedding amount was proposed to modify the scheme. This approach was applied to IEEE-39 system and the simulation results indicated that the proposed method was effective in reducing the load shedding amount as well as the frequency recovery time.
منابع مشابه
بهبود پایداری شبکه قدرت با روش جدید حذف بار ترکیبی
Power system blackouts have become a serious problem for electric utilities especially in recent years. Different forms of system instability have emerged in recent blackouts, such as voltage instability and frequency instability. To counteract each form of system instability, special algorithms have been designed in the protection system, e.g. Under Frequency Load Shedding (UFLS) and Under Vol...
متن کاملUnder-Frequency Load Shedding (UFLS) Schemes – A Survey
The Under-frequency Load Shedding (UFLS) scheme has been used by utility companies around the world to mitigate frequency drop caused by simultaneous or cascading tripping of transmission lines and/or generators in a power system. In the effort to devise an optimal load shedding scheme, it is imperative that investigations are done on the many factors that may affect the response of the scheme ...
متن کاملارائه الگوریتم حذف بار وفقی جهت حفاظت سیستم قدرت در مقابل حوادث ترکیبی منجر به خاموشی سراسری
In recent years several catastrophic power systems blackouts have occurred worldwide. Various reasons have been declared for these failures. Economical limitations due to power system restructuring restrictions, inadvertent operation of protective relays and inefficient design of conventional load shedding schemes are of the most important reasons causing these blackouts. In fact, due to both e...
متن کاملAn Improved Under-Frequency Load Shedding Scheme in Distribution Networks with Distributed Generation
When a distribution network consisting of Distributed Generations (DGs) is disconnected from upstream network, the system may be exposed to severe power imbalance. In order to prevent the damage of power plants, frequency relays operate and remove DGs from the network. In contrast to traditional methods, the main objective in new methods is to keep DG units in service in the islanded distributi...
متن کاملSwarm Evolutionary Programming for Under-Frequency Load Shedding
In this paper, Swarm Evolutionary Programming (SEP) method incorporating modified System Frequency Response (SFR) model is proposed to solve the optimal Under-frequency Load Shedding (UFLS) scheme design problem. The objective function of this problem is to minimize transient frequency and steady-state frequency deviation from nominal and total quantum of load shedding. The constrained optimiza...