A benchtop closed-loop system controlled by a bio-inspired silicon implementation of the pancreatic beta cell.
نویسندگان
چکیده
UNLABELLED The normal pancreatic beta-cell membrane depolarizes in response to increasing concentrations of glucose in a bursting pattern. At <7 mM (126 mg/dl), the cell is electrically silent. The bursting pulse width increases as glucose rises >7 mM (126 mg/dl) until a continuous train of bursting is seen at >25 mM (450 mg/dl). A bio-inspired silicon device has been developed using analogue electronics to implement membrane depolarization of the beta cell. The device is ultralow powered, miniaturized (5 x 5 mm), and produces a bursting output identical to that characterized in electrophysiological studies. OBJECTIVE The goal of this study was to demonstrate the ability of silicon implementation of beta-cell electrophysiology to respond to a simulated glucose input and to drive an infusion pump in vitro. METHOD The silicon device response to a current source was recorded at varying simulated glucose concentrations. Subsequently, the bursting response to a changing analyte concentration measured by an amperometric enzyme electrode was converted to a voltage, driving a syringe pump loaded with a 50-ml syringe containing water. RESULTS Bursting responses are comparable to those recorded in electrophysiology. Silicon beta-cell implementation bursts with a pulse width proportional to concentration and is able to drive an infusion pump. CONCLUSION This is the first in vitro demonstration of closed loop insulin delivery utilizing miniaturized silicon implementation of beta-cell physiology in analogue electronics.
منابع مشابه
Bio-Inspired Controller on an FPGA Applied to Closed-Loop Diaphragmatic Stimulation
Cervical spinal cord injury can disrupt connections between the brain respiratory network and the respiratory muscles which can lead to partial or complete loss of ventilatory control and require ventilatory assistance. Unlike current open-loop technology, a closed-loop diaphragmatic pacing system could overcome the drawbacks of manual titration as well as respond to changing ventilation requir...
متن کاملA Closed Loop Control of Quadratic Boost Converter Using PID Controller
This paper presents an implementation of open loop and closed loop control of Quadratic boost converter using PID controller. Quadratic boost converter consists of boost converter and fly back converter driven by a single switch. Quadratic boost converter QBC is designed especially for regulating the DC interface between various micro sources and dc-ac inverter to electricity grid. Quadratic b...
متن کاملPractical Implementation of Scalar and Vector Control Methods on a Rotor Surface Type Permanent Magnent Synchronous Machine Drive/System Using a PC
In this paper, using a personal computer (PC), the practical implementation of scalar and vector control methods on a three–phase rotor surface- type permanent magnet synchronous machine drive is discussed. Based on the machine dynamic equations and the above control strategies, two block diagrams are presented first for closed-loop speed controlling of the machine drive/system. Then, the desig...
متن کاملPractical Implementation of Scalar and Vector Control Methods on a Rotor Surface Type Permanent Magnent Synchronous Machine Drive/System Using a PC
In this paper, using a personal computer (PC), the practical implementation of scalar and vector control methods on a three–phase rotor surface- type permanent magnet synchronous machine drive is discussed. Based on the machine dynamic equations and the above control strategies, two block diagrams are presented first for closed-loop speed controlling of the machine drive/system. Then, the desig...
متن کاملControl of Flexible Link Robot using a Closed Loop Input-Shaping Approach
This paper is has addressed the Single Flexible Link Robot. The dynamical model is derived using Euler-Lagrange equation and then a proper controller is designed to suppress a vibration based-on Input-Shaping (IS) method. But, IS control method is an open loop strategy. Due to the weakness of open loop control systems, a closed loop IS control system is proposed. The achieved closed loop c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 3 6 شماره
صفحات -
تاریخ انتشار 2009