Effects of tilt on high-resolution ADF-STEM imaging.

نویسندگان

  • S E Maccagnano-Zacher
  • K A Mkhoyan
  • E J Kirkland
  • J Silcox
چکیده

A study of the effects of small-angle specimen tilt on high-resolution annular dark field images was carried out for scanning transmission electron microscopes with uncorrected and aberration-corrected probes using multislice simulations. The results indicate that even in the cases of specimen tilts of the order of 1 degree a factor of 2 reduction in the contrast of the high-resolution image should be expected. The effect holds for different orientations of the crystal. Calculations also indicate that as the tilted specimen gets thicker the contrast reduction increases. Images simulated with a low-angle annular dark field detector show that tilt effects are more pronounced in this case and suggest that these low-angle detectors can be used to correct specimen tilt during scanning transmission electron microscopes operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining the thickness of atomically thin MoS2 and WS2 in the TEM.

Multislice simulations were used to analyze the reliability of annular dark field scanning transmission electron microscopy (ADF-STEM) imaging and selected-area electron diffraction (SAED) for determining the thicknesses of MoS2 and WS2 specimens in the aberration-corrected TEM. Samples of 1 to 4 layers in thickness for both 2H and 1T polymorphs were studied and tilts up to 500mrad off of the [...

متن کامل

Identifying hexagonal boron nitride monolayers by transmission electron microscopy.

Multislice simulations in the transmission electron microscope (TEM) were used to examine changes in annular-dark-field scanning TEM (ADF-STEM) images, conventional bright-field TEM (BF-CTEM) images, and selected-area electron diffraction (SAED) patterns as atomically thin hexagonal boron nitride (h-BN) samples are tilted up to 500 mrad off of the [0001] zone axis. For monolayer h-BN the contra...

متن کامل

Noninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI

Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...

متن کامل

Effects of amorphous layers on ADF-STEM imaging.

A study of high-resolution ADF imaging in uncorrected and aberration-corrected STEMs was carried out by multislice simulation. The presence of amorphous layers at the surface of a crystalline specimen is shown to significantly alter the visibility of the atomic columns. After propagating through an amorphous layer a portion of the beam passes without any alteration while scattered electrons int...

متن کامل

Single atomic layer detection of Ca and defect characterization of Bi-2212 with EELS in HA-ADF STEM.

By forming a small electron probe in a scanning transmission electron microscope equipped with a high-angle annular dark-field (HA-ADF) detector, the Bi-O atomic planes in Bi2Sr2CaCu2O(8+delta) (Bi-2212) can be directly observed with the incoherent Z-contrast imaging technique. Using a combination of electron energy loss spectroscopy (EELS) and HA-ADF imaging, we were able to detect the Ca sign...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 108 8  شماره 

صفحات  -

تاریخ انتشار 2008