Locked plate fixation of the comminuted distal fibula: a biomechanical study.

نویسندگان

  • Neil J White
  • David T Corr
  • James P Wagg
  • Caeley Lorincz
  • Richard E Buckley
چکیده

BACKGROUND The purpose of this study was to compare the biomechanical properties of locked versus nonlocked lateral fibular bridge plating of comminuted, unstable ankle fractures in a mode of catastrophic failure. METHODS We created comminuted Weber C fractures in 8 paired limbs from fresh cadavers. Fractures were plated with either standard or locked one-third tubular bridge plating techniques. Specimens were biomechanically evaluated by external rotation to failure while subjected to a compressive load approximating body weight. We measured the angle to failure, torque to failure, energy to failure and construct stiffness. RESULTS There was no significant difference in construct stiffness or other biomechanical properties between locked and standard one-third tubular plating techniques. CONCLUSION We found no difference in biomechanical properties between locked and standard bridge plating of a comminuted Weber C fibular fracture in a model of catastrophic failure. It is likely that augmentation of fixation with K-wires or transtibial screws provides a construct superior to locked bridge plating alone. Further biomechanical and clinical analysis is required to improve understanding of the role of locked plating in ankle fractures and in osteoporotic bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Benefits of the VariAx Distal Lateral Fibula Plate

Distal fibula fractures are the most common injury of weight bearing bones. Several studies have shown the benefit of locking plates especially in osteoporotic bone. The aim of this biomechanical study was to test the anatomically shaped VariAx Distal Lateral Fibula Plate in comparison to a commonly used 1/3 Tubular Plate. The implants were assembled to bone surrogates simulating a comminuted f...

متن کامل

Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study.

OBJECTIVES The purpose of this study was to compare the biomechanical properties of posterolateral antiglide plating and lateral locked plating for fixation of displaced short oblique fractures of the fibula in osteoporotic bone. METHODS Short oblique fractures of the distal fibula at the level of the syndesmosis were simulated with a fibular osteotomy and ligamentous sectioning in 18 paired ...

متن کامل

Immediate weight bearing of comminuted supracondylar femur fractures using locked plate fixation.

Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, som...

متن کامل

Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia

Background:  Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

متن کامل

A contoured locking plate: Biomechanical evaluation of an osteosynthesis for osteoporotic ankle fractures

Introduction Ankle fractures involving the distal fibula belong to the most common fractures. Operative treatment is indicated in unstable ankle fractures by open reduction and internal fixation with plate and screws. Especially in the elderly, the osteoporotic bone provides reduced stabilization of this fixation. Therefore, an implant providing improved mechanical stabilization could allow a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 56 1  شماره 

صفحات  -

تاریخ انتشار 2013