Error quantification in calibration of AFM probes due to non-uniform cantilevers
نویسندگان
چکیده
For more than two decades, the Atomic Force Microscope (AFM) has provided valuable insights in nanoscale phenomena, and it is now widely employed by scientists from various disciplines. AFMs use a cantilever beam with a sharp tip to scan the surface of a sample both to image it and to perform mechanical testing. The AFM measures the deflection of the probe beam so one must first find the spring constant of the cantilever in order to estimate the force between the sample and the probe tip. Commonly applied calibration methods regard the probe as a uniform cantilever, neglecting the tip mass and any nonuniformity in the thickness along the length of the beam. This work explores these issues, recognizing that dynamic calibration boils down to finding the modal parameters of a dynamic model for a cantilever from experimental measurements and then using those parameters to estimate the static stiffness of a probe; if the modes of the cantilever are not what was expected, for example because the non-uniformity was neglected, then the calibration will be in error. This work explores the influence of variation in the thickness of a cantilever probe along its length on its static stiffness as well as its dynamics, seeking to determine when the uniform beam model that is traditionally employed is not valid and how one can ascertain whether the model is valid from measurable quantities. The results show that the Sader method is quite robust to non-uniformity so long as only the first dynamic mode is used in the calibration. The thermal method gives significant errors for the non-uniform probe studied here. Nomenclature αn n th frequency parameter M Moment b cantilever width ψn nth mode shape E Young’s modulus ωn natural frequency F force Q quality factor Γ hydrodynamic function ρ cantilever density h cantilever thickness ρf density of the surrounding fluid I second moment of area T temperature ks spring constant w deflection kB Boltzmann’s constant W static deflection L cantilever length χ optical lever factor m mass x coordinate along beam axis
منابع مشابه
Uncertainty Quanti cation in Calibration of AFM Probes Due to Non-uniform Cantilevers
For more than two decades, the Atomic Force Microscope (AFM) has provided valuable insights in nanoscale phenomena, and it is now widely employed by scientists from various disciplines. AFMs use a cantilever beam with a sharp tip to scan the surface of a sample both to image it and to perform mechanical testing. Since the AFM measures the de ection of the probe beam, one must rst nd the spring ...
متن کاملGDQEM Analysis for Free Vibration of V-shaped Atomic Force Microscope Cantilevers
V-shaped and triangular cantilevers are widely employed in atomic force microscope (AFM) imaging techniques due to their stability. For the design of vibration control systems of AFM cantilevers which utilize patched piezo actuators, obtaining an accurate system model is indispensable prior to acquiring the information related to natural modes. A general differential quadrature element method (...
متن کاملQuantitative analytical atomic force microscopy: a cantilever reference device for easy and accurate AFM spring-constant calibration
Calibration of atomic force microscope (AFM) cantilevers is necessary for the measurement of nanonewton and piconewton forces, which are critical to analytical applications of AFM in the analysis of polymer surfaces, biological structures and organic molecules. We have developed a compact and easy-to-use reference artefact for this calibration by bulk micromachining of silicon, which we call a ...
متن کاملEffect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.
Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, wh...
متن کاملCalibration of atomic force microscope cantilevers using piezolevers.
The atomic force microscope (AFM) can provide qualitative information by numerous imaging modes, but it can also provide quantitative information when calibrated cantilevers are used. In this article a new technique is demonstrated to calibrate AFM cantilevers using a reference piezolever. Experiments are performed on 13 different commercially available cantilevers. The stiff cantilevers, whose...
متن کامل