Effect of air-flow on the evaluation of refractive surgery ablation patterns.

نویسندگان

  • Carlos Dorronsoro
  • Silvia Schumacher
  • Pablo Pérez-Merino
  • Jan Siegel
  • Michael Mrochen
  • Susana Marcos
چکیده

An Allegretto Eye-Q laser platform (Wavelight GmbH, Erlangen, Germany) was used to study the effect of air-flow speed on the ablation of artificial polymer corneas used for testing refractive surgery patterns. Flat samples of two materials (PMMA and Filofocon A) were ablated at four different air flow conditions. The shape and profile of the ablated surfaces were measured with a precise non-contact optical surface profilometer. Significant asymmetries in the measured profiles were found when the ablation was performed with the clinical air aspiration system, and also without air flow. Increasing air-flow produced deeper ablations, improved symmetry, and increased the repeatability of the ablation pattern. Shielding of the laser pulse by the plume of smoke during the ablation of plastic samples reduced the central ablation depth by more than 40% with no-air flow, 30% with clinical air aspiration, and 5% with 1.15 m/s air flow. A simple model based on non-inertial dragging of the particles by air flow predicts no central shielding with 2.3 m/s air flow, and accurately predicts (within 2 μm) the decrease of central ablation depth by shielding. The shielding effects for PMMA and Filofocon A were similar despite the differences in the ablation properties of the materials and the different full-shielding transmission coefficient, which is related to the number of particles ejected and their associated optical behavior. Air flow is a key factor in the evaluation of ablation patterns in refractive surgery using plastic models, as significant shielding effects are found with typical air-flow levels used under clinical conditions. Shielding effects can be avoided by tuning the air flow to the laser repetition rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of optimized ablation patterns for laser refractive surgery.

A new experimental model based on plastic (Filofocon A) artificial eyes was used to study the ablation profiles and the outcomes of three state-of-the-art refractive surgery excimer lasers provided with narrow-beam flying spot and optimized algorithms (Ladarvision 4000, Alcon; Technolas 217 Z100, Bausch and Lomb; Allegretto wave Eye-Q, Wavelight). The 3-D ablation patterns produced by myopic la...

متن کامل

Surface temperature change of pmma plateS in refractive Surgery performed with two typeS of modern excimer laSerS

Introduction. the conditions in the operating room can have an influence on the postoperative results of the refractive surgery performed with excimer lasers. Aim. the aim of this study was to examine the relationship of the temperature of pmma plates (polymethylmethacrylate), environmental conditions and the energy load caused by the laser impulses during refractive surgery procedure. Material...

متن کامل

Experimental Results of Pressure Fluctuations in a Water Conduit Section Due to Formation of Unstable Two-Phase Air-Water Flow

The study of two-phase fluid flow behavior in hydraulic structures such as pressurized flow tunnels, culverts, sewer pipes, junctions and other similar conduits is of great importance. A two-phase mixture flowing in a pipe can exhibit several interfacial geometries such as bubbles, slugs or films, depending on the fluid and hydrodynamic properties of flow. The main variables, giving rise to a v...

متن کامل

Evaluation of Health Housing Characteristics in Kashan; Case study: Air Health

Today, the issue of providing health through environmental regulation has become an urgent need. The main issue of this research is to find the indicators and pattern of the type of housing that provides health through air, ventilation and respiration based on traditional medicine. The research is further aimed at studying successful examples of traditional and contemporary housing in Kashan to...

متن کامل

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2011