TOF-MRA using multi-oblique-stack acquisition (MOSA).

نویسندگان

  • Ed X Wu
  • Edward S Hui
  • Jerry S Cheung
چکیده

PURPOSE To alleviate the intrinsic limitation of current time-of-flight magnetic resonance angiography (TOF-MRA) techniques, which are insensitive to in-plane blood flow due to the flow saturation effect. MATERIALS AND METHODS A multi-oblique-stack acquisition (MOSA) technique was proposed in this study to tackle this TOF problem by acquiring two or more TOF image stacks bearing different orientations. The MOSA approach was evaluated in human brain MR angiograms by integrating it with the widely used multiple overlapping thin-slab acquisition (MOTSA) technique. Two TOF image sets in different orientations were acquired using MOTSA. They were combined pixel-by-pixel by taking the maximum intensity value. Maximum intensity projection (MIP) was then performed, and the resulting MRA quality was assessed. RESULTS The results demonstrated that MR angiograms obtained by MOSA-MOTSA were clearly improved compared to those acquired by conventional MOTSA in the same scan time. CONCLUSION MOSA clearly demonstrates its advantage over conventional TOF acquisition in visualizing in-plane blood flows.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non contrast MR Angio by intrinsic dephasing of true FISP SMS: Ssfp Minus Ssfp

Introduction: Contrast enhanced MRA is widely used due to the large blood signal, the fast acquisition and decreased motion artifacts at high spatial resolution. Very fast sequences and a proper timing of the high dose contrast bolus with the data acquisition, allows the separation of arterial from venous blood vessels. However, in patients with high risk for developing NSF (Nephrogenic Systemi...

متن کامل

Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: a comparison with time-of-flight MR angiography.

The combination of 3T and parallel-acquisition techniques holds promise for improved performance of contrast-enhanced MR angiography (MRA), in terms of speed, spatial resolution, and coverage. We present a comparison of 2 MRA techniques, including time-of-flight (TOF) and contrast-enhanced MRA, for detection and evaluation of intracranial aneurysms. Our results show that contrast-enhanced MRA w...

متن کامل

Fast Inversion Recovery Magnetic Resonance Angiography (FIR-MRA) of the Intracranial Arteries

Introduction –3D time-of-flight (TOF) [1] provides excellent vessel-to-background contrast in intracranial MRA, but is subject to inplane saturation and incomplete venous suppression. Spin-labeling [2-3] may be used to perform MRA [4-5], but typically requires long inversion intervals with inherently long acquisition times. We have developed a 3D fast inversion recovery MRA (FIR-MRA) that uses ...

متن کامل

Towards True Arterial Intracranial TOF-MRA at 7T: Protocol Optimization Using VERSE Pulses

Introduction It has been shown that the visibility of the vasculature in time-offlight (TOF) MR-angiography highly profits from increased field strengths [1-4]. To acquire truly arterial TOF data sets, the MR signal of venous blood is often saturated using spatially selective saturation pulses. Because of SAR limitations, the application of additional saturation pulses is often not possible at ...

متن کامل

Prediction of infarction and reperfusion in stroke by flow- and volume-weighted collateral signal in MR angiography.

BACKGROUND AND PURPOSE In proximal anterior circulation occlusive strokes, collateral flow is essential for good outcome. Collateralized vessel intensity in TOF- and contrast-enhanced MRA is variable due to different acquisition methods. Our purpose was to quantify collateral supply by using flow-weighted signal in TOF-MRA and blood volume-weighted signal in contrast-enhanced MRA to determine e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2007