Impact of x-ray dose on the response of CR-39 to 1-5.5 MeV alphas.
نویسندگان
چکیده
The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-Kα and Kβ x-rays. The CR-39 detectors were then exposed to 1-5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula.
منابع مشابه
Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum
Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...
متن کاملThe response of CR-39 nuclear track detector to 1-9 MeV protons.
The response of CR-39 nuclear track detector (TasTrak(®)) to protons in the energy range of 0.92-9.28 MeV has been studied. Previous studies of the CR-39 response to protons have been extended by examining the piece-to-piece variability in addition to the effects of etch time and etchant temperature; it is shown that the shape of the CR-39 response curve to protons can vary from piece-to-piece....
متن کاملConsider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.
Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....
متن کاملProton beam dosimetry by CR-39 track-etched detector
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
متن کاملبررسی تابش کانالی از بلورهای الماس به منظور تهیه پرتو X تک انرژی درشتاب دهنده خطی الکترون ELBE
The measurements of electron Channeling Radiation (CR) have been performed at ELBE linear electron accelerator of the Forschungszentrum Dresden-Rossendorf. The aim of performing these experiments was to optimize radiation yield and spectral line width of CR in order to apply channeling radiation for preparing a monochromatic X-ray source. Diamond crystals can be used in relatively high electron...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 86 3 شماره
صفحات -
تاریخ انتشار 2015