The present status of the VIRGO Central Interferometer*
نویسندگان
چکیده
The VIRGO Central Interferometer (CITF) is a short suspended interferometer operated with the central area elements of the VIRGO detector. The main motivation behind the CITF is to allow the integration and debugging of a large part of the subsystems of VIRGO while the construction of the long arms of the antenna is being completed. This will permit a faster commissioning of the full-size antenna. In fact, almost all the main components of the CITF, with the exception of the large mirrors and a few other details, are the same as those to be used for the full-size detector. In this paper the present status of the VIRGO CITF is reported.
منابع مشابه
Automatic Mirror Alignment for VIRGO: First experimental demonstration of the Anderson technique on a large-scale interferometer
The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson laser interferometer with 3 km long optical cavities in the arms and a power-recycling mirror. The interferometer resides in an ultra-high vacuum system and the mirrors are suspended from multistage pendulums for seismic isolation. This type of laser inte...
متن کاملCommissioning status of the Virgo interferometer
The Virgo interferometer is one of the big observatories aimed at detecting gravitational waves. This report will describe the Virgo+ upgrades and the commissioning work performed between the first (VSR1) and the second Virgo Science Run (VSR2). Some first results of VSR2 will be discussed, which was recently started with a good duty cycle and a inspiral range for the detection of binary neutro...
متن کاملar X iv : g r - qc / 0 40 61 23 v 1 3 0 Ju n 20 04 Status of VIRGO *
The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson interferometer with 3 km long optical cavities in the arms and a powerrecycling mirror. This paper gives an overview of the present status of the system. We report on the presently attained sensitivity and the system’s performance during the recent commis...
متن کاملar X iv : g r - qc / 9 61 10 27 v 1 1 1 N ov 1 99 6 Alignment procedure for the VIRGO Interferometer : experimental results from the Frascati prototype
A small fixed-mirror Michelson interferometer has been built in Frascati to experimentally study the alignment method that has been suggested for VIRGO. The experimental results fully confirm the adequacy of the method. The minimum angular misalignment that can be detected in the present setup is 10 nrad/ √ Hz.
متن کاملActive Controls in Interferometric Detectors of Gravitational Waves: Inertial Damping of the Virgo Superattenuator
The operation of an interferometer for gravitational waves detection requires sophisticated feedback controls in many parts of the apparatus. The aim of this lecture is to introduce the types of problems to be faced in this line of research. The attention is focused on the inertial damping of the test mass suspension of the VIRGO interferometer (the superattenuator): it is a multidimensional lo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002