Comparison of total coliform, fecal coliform, and enterococcus bacterial indicator response for ocean recreational water quality testing.
نویسندگان
چکیده
In July 1999, California's ocean recreational bacterial water quality standards were changed from a total coliform (TC) test to a standard requiring testing for all three bacterial indicators: TC, fecal coliforms (FC), and enterococci (EC). To compare the relationship between the bacterial indicators, and the effect that changing the standards would have on recreational water regulatory actions, three regional studies were conducted along the southern California shoreline from Santa Barbara to San Diego, California. Two studies were conducted during dry weather and one following a large storm event. In each study, samples were collected at over 200 sites which were selected using a stratified random design, with strata consisting of open beach areas and rocky shoreline, and areas near freshwater outlets that drain land-based runoff. During the dry weather studies, samples were collected once per week for 5 weeks. For the storm event study, sampling occurred on a single day about 24 h following the storm. The three indicator bacteria were measured at each site and the results were compared to the single sample standards (TC > 10,000; FC > 400 and EC > 104 MPN or cfu/100 ml). EC was the indicator that failed the single sample standards most often. During the wet weather study, 99% of all standard failures were detected using EC, compared with only 56% for FC, and 40% for TC. During the Summer Study, EC was again the indicator that failed the single sample standards most often, with 60% of the failures for EC alone. The increased failure of the EC standard occurred consistently regardless of whether the sample was collected at a beach or rocky shoreline site, or at a site near a freshwater outlet. Agreement among indicators was better during wet weather than during dry weather. During dry weather, agreement among indicators was better near freshwater outlets than along open shoreline. Cumulatively, our results suggest that replacement of a TC standard with an EC standard will lead to a five-fold increase in failures during dry weather and a doubling of failures during wet weather. Replacing a TC standard with one based on all three indicators will lead to an eight-fold increase in failures. Changes in the requirements for water quality testing have strong implications for increases in beach closures and restrictions.
منابع مشابه
تعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN
Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...
متن کاملRelationship between Turbidity and Residual Chlorine and Microbial Quality of Drinking Water
Abstract Background and Objective: Safe drinking water is essential for health and health promotion is dependent on providing safe water. We aimed to determine the relationship between turbidity & residual chlorine and microbial quality of drinking water in Agh ghala. Material and Methods: In this descriptive-analytical study, 2079 water samples were collected from water networks of 78 ...
متن کاملRelationship between rainfall and beach bacterial concentrations on Santa Monica bay beaches.
Rainfall effects on beach water quality in southern California are large enough that county health departments typically issue warnings for the public to avoid recreational water contact for 3 days following a storm. To enhance the scientific foundation for these preemptive public health warnings, we examined the relationship between rainfall and beach indicator bacteria concentrations using 5 ...
متن کاملComparison of two methods for detection of fecal indicator bacteria used in water quality monitoring of the Three Gorges Reservoir.
Scientifically sound methods to rapidly measure fecal indicator bacteria are important to ensure safe water for drinking and recreational purposes. A total of 200 water samples obtained from the Three Gorges Reservoir during three successive one-year study periods (October 2009 to September 2012) were analyzed using multiple-tube fermentation (MTF) and most probable numbers combined with polyme...
متن کاملIsolation and Identification of Pathogenic Bacteria from Drinking Water
Drinking water microbiological quality was primarily determined by enumeration of “indicator organisms”, whose presence indicates faecal contamination. The presence of the indicators is often a key in assessing potential public health risks due to bacterial pathogens and is used in drinking water quality regulations and guidelines in many countries. The enumeration of fecal coliform specificall...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 37 7 شماره
صفحات -
تاریخ انتشار 2003