Bias in Ligation-Based Small RNA Sequencing Library Construction Is Determined by Adaptor and RNA Structure
نویسندگان
چکیده
High-throughput sequencing (HTS) has become a powerful tool for the detection of and sequence characterization of microRNAs (miRNA) and other small RNAs (sRNA). Unfortunately, the use of HTS data to determine the relative quantity of different miRNAs in a sample has been shown to be inconsistent with quantitative PCR and Northern Blot results. Several recent studies have concluded that the major contributor to this inconsistency is bias introduced during the construction of sRNA libraries for HTS and that the bias is primarily derived from the adaptor ligation steps, specifically where single stranded adaptors are sequentially ligated to the 3' and 5'-end of sRNAs using T4 RNA ligases. In this study we investigated the effects of ligation bias by using a pool of randomized ligation substrates, defined mixtures of miRNA sequences and several combinations of adaptors in HTS library construction. We show that like the 3' adaptor ligation step, the 5' adaptor ligation is also biased, not because of primary sequence, but instead due to secondary structures of the two ligation substrates. We find that multiple secondary structural factors influence final representation in HTS results. Our results provide insight about the nature of ligation bias and allowed us to design adaptors that reduce ligation bias and produce HTS results that more accurately reflect the actual concentrations of miRNAs in the defined starting material.
منابع مشابه
Small-RNA sequencing libraries with greatly reduced adaptor-dimer background
Conventional methods for preparing small-RNA–seq libraries by adaptor ligation generate a significant amount of adaptor dimer, thereby resulting in wasted sequencing reads. These methods also do not capture small 5’-capped and 5’-triphosphorylated RNAs. The ScriptMinerTM small-RNA–seq library preparation technology overcomes these limitations. ScriptMinerTM small-RNA libraries contain greatly r...
متن کاملCDNA library construction from a small amount of RNA: adaptor-ligation approach for two-round cRNA amplification using T7 and SP6 RNA polymerases.
In this study, we developed a method that allows cDNA library construction from a small amount of RNA without causing serious size bias in the resulting cDNA population. For this purpose, we adopted two-round cRNA amplification by T7 and SP6 RNA polymerases. The first-round cDNAs, flanked by the promoter sequences of T7 and SP6 RNA polymerases, were synthesized from 1 microg total RNA and then ...
متن کاملAddressing Bias in Small RNA Library Preparation for Sequencing: A New Protocol Recovers MicroRNAs that Evade Capture by Current Methods
Recent advances in sequencing technology have helped unveil the unexpected complexity and diversity of small RNAs. A critical step in small RNA library preparation for sequencing is the ligation of adapter sequences to both the 5' and 3' ends of small RNAs. Studies have shown that adapter ligation introduces a significant but widely unappreciated bias in the results of high-throughput small RNA...
متن کاملMassively differential bias between two widely used Illumina library preparation methods for small RNA sequencing
Recent advances in sequencing technology have helped unveil the unexpected complexity and diversity of small RNAs. A critical step in small RNA library preparation for sequencing is the ligation of adapter sequences to both the 5’ and 3’ ends of small RNAs. Two widely used protocols for small RNA library preparation, Illumina v1.5 and Illumina TruSeq, use different pairs of adapter sequences. I...
متن کاملQuantitative Bias in Illumina TruSeq and a Novel Post Amplification Barcoding Strategy for Multiplexed DNA and Small RNA Deep Sequencing
Here we demonstrate a method for unbiased multiplexed deep sequencing of RNA and DNA libraries using a novel, efficient and adaptable barcoding strategy called Post Amplification Ligation-Mediated (PALM). PALM barcoding is performed as the very last step of library preparation, eliminating a potential barcode-induced bias and allowing the flexibility to synthesize as many barcodes as needed. We...
متن کامل