Endovascular aortic aneurysm repair using a bifurcated stent graft in a patient with femoro-femoral bypass

نویسندگان

  • Su Hwan Kang
  • Jung Min Bae
  • Woo-Sung Yun
چکیده

A challenging iliac anatomy remains a major obstacle to successful endovascular aortic aneurysm repair. The authors experienced an abdominal aortic aneurysm with bilateral common iliac artery aneurysms in a patient that had undergone femoro-femoral bypass due to left external iliac artery (EIA) occlusion. To treat this patient in a totally endovascular manner, a bifurcated stent graft was used. One iliac limb was deployed in the right internal iliac artery (IIA) and the other in the right EIA; the left IIA was embolized with coils. Here, the authors describe the procedure used and provide technical tips.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aorto-Uni-Iliac Stent Grafting and Femoro-Femoral Bypass in a Patient with a Failed and Catastrophic Endovascular Aortic Aneurysm Repair

A 78-year-old man presented at Eulji University Hospital due to an abdominal aortic aneurysm with maximum diameter of 52 mm, which had been increased from 45 mm over 6 months. He underwent embolization of the left internal iliac artery with vascular plug, prior to endovascular abdominal aortic repair with a bifurcated stent graft system. Unfortunately, the inserted vascular plug was maldeployed...

متن کامل

Late type IIIb endoleak after endovascular aneurysm repair: case report and review of the literature.

PURPOSE To report a case of type IIIb endoleak developed six years after endovascular abdominal aortic aneurysm repair (EVAR). CASE REPORT A 75-year-old man underwent successful Talent™ stent-graft positioning to treat a 53 mm abdominal aortic aneurysm. Subsequently the patient did well and yearly routine control computerized tomography (CT) was unremarkable. Six years later the patient sudde...

متن کامل

The role of aortouniiliac devices in the treatment of aneurysmal disease.

PURPOSE Many studies have shown that aortouniiliac (AUI) devices have comparable outcome in high risk patients as the treatment with bifurcated devices. The purpose of this article is to review the relevant literature and discuss the outcomes. METHODS A systematic search from 1991 until 2010 was performed on PubMed and Medline databases for studies evaluating the role of AUI devices accompani...

متن کامل

In Situ Aortic Reconstruction with Femoral Vein after Post-EVAR Infection

A 78-year-old male presented with early gastric cancer and a 5.5 cm-sized infrarenal abdominal aortic aneurysm, detected during regular screening. Endovascular aneurysm repair (EVAR) was performed first, followed by laparoscopic distal gastrectomy. After gastrectomy, the patient underwent computed tomography (CT) scan due to persistent fever, which showed increased perigraft fluid collection ar...

متن کامل

Successful rescue of the ruptured chronic B dissecting aneurysm after endovascular stent-graft with supraclavicular carotid artery graft cannulation

Method A 44-year-old patient underwent the TEVAR with chimney technique of left subclavian artery in a life-threatening situation of type B chronic dissecting aneurysm with rupture. A follow-up CT scan showed the proximal type I endoleak with high pressurized aneurysm 5 days later. The graft explanation and open repair were performed emergently. Via a left supraclavicular incision, the end-to s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 89  شماره 

صفحات  -

تاریخ انتشار 2015