Evaluation of image quality of a 32-channel versus a 12-channel head coil at 1.5T for MR imaging of the brain.

نویسندگان

  • P T Parikh
  • G S Sandhu
  • K A Blackham
  • M D Coffey
  • D Hsu
  • K Liu
  • J Jesberger
  • M Griswold
  • J L Sunshine
چکیده

BACKGROUND AND PURPOSE Multichannel phased-array head coils are undergoing exponential escalation of coil element numbers. While previous technical studies have found gains in SNR and spatial resolution with the addition of element coils, it remains to be determined how these gains affect clinical reading. The purpose of this clinical study was to determine if the SNR and spatial resolution characteristics of a 32-channel head coil result in improvements in perceived image quality and lesion evaluation. MATERIALS AND METHODS Twenty-one patients underwent MR imaging of the brain at 1.5T sequentially with both a 12-channel and a 32-channel receive-only phased-array head coil. Axial T2WIs, T1WIs, FLAIR images, and DWIs were acquired. Anonymized images were compared side-by-side and by sequence for image quality, lesion evaluation, and artifacts by 3 neuroradiologists. Results of the comparison were analyzed for the preference for a specific head coil. RESULTS FLAIR and DWI images acquired with the 32-channel coil showed significant improvement in image quality in several parameters. T2WIs also improved significantly with acquisition by the 32-channel coil, while T1WIs improved in a limited number of parameters. While lesion evaluation also improved with acquisition of images by the 32-channel coil, there was no apparent improvement in diagnostic quality. There was no difference in artifacts between the 2 coils. CONCLUSIONS Improvements in SNR and spatial resolution attributed to image acquisition with a 32-channel head coil are paralleled by perceived improvements in image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

A 32-channel Receive Array Coil for Pediatric Brain Imaging at 3T

Introduction: Pediatric MRI currently requires general anesthesia to preclude motion artifacts. With highly accelerated image encoding in conjunction motion navigators it may be possible to significantly reduce or even eliminate anesthesia. For research studies of brain development where anesthesia is not possible, improved motion robustness can significantly improve the success rate. Highly pa...

متن کامل

Comparison of a 32-channel with a 12-channel head coil: are there relevant improvements for functional imaging?

PURPOSE To evaluate the suitability of a 12- or 32-channel head coil and of a prescan normalization filter for functional magnetic resonance imaging (fMRI) studies at different brain regions. MATERIALS AND METHODS fMRI was obtained from 36 volunteers executing a visually instructed motor paradigm using a 12-channel head matrix coil and a 32-channel phased-array head coil with and without pres...

متن کامل

Whole-body MRI: comprehensive evaluation on a 48-channel

Objective: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/ inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. Materials and Methods: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2011