Meeting Report
نویسنده
چکیده
exhibited their new instruments in 1400 booths. Of the 900 papers presented at the conference, the following from the symposium on 'Process analysers' dealt with automated stream analysis for process control. Gibbon and Hackett [1] described the use of automated research-quality gas chromatographs to analyse the effluents from bench-scale coal gasification or liquefaction equipment. The high specificity of process-control chromatographs is a disadvantage if the process gas stream being monitored is undergoing rapid and wide changes in chemical composition; this happens during process development. For example the gas composition, during an experimental run of a bench-scale coal liquefaction or gasification process development unit, may include pure nitrogen during the initial purge, unreacted feed-gas during start-up, and a variety of product compositions during the reaction phase of the experiment. Another common approach to monitoring these gases is taking 'grab' gas samples for subsequent laboratory analysis. Such an approach is labour intensive, and it is slow relative to the time scale of an on-line analysis. An alternative to this 'grab'-sampling approach is the attachment of automated research-quality gas chromatographs directly to the coal gasification or liquefaction equipment. The degree of automation of these chromatographs is defined by the analyst and may include a fully automated system that requires virtually no operator attention during routine operation. This eliminates sampling errors, eases manpower needs and time delays. Gibbon and Hackett describe the use of Hewlett Packard 5730 gas chromatograph, with dual thermal conductivity cells, to handle routine gas analysis. Five gases, hydrogen, nitrogen, methane, carbon monoxide and carbon dioxide, can be analysed, as well as hydrocarbons (up to four carbons), hydrogen sulphide and water vapour. The columns used are (a) a 60/80 mesh 5A molecular sieve, 1/8 in. OD by 10 ft. stainless steel with argon as carrier gas; (b) an 80/100 mesh Porapak 'R', 1/8 in. OD by 12 ft. stainless steel with helium as the carrier gas. The columns and detectors are operated at 100C, bridge currents are 120mA (argon carrier) and 250 mA (helium carrier) and the carrier gas flow rate is 20cc/min. Samples are injected using an air-activated Valco six-port gas-sampling valve; a 'flow type' sampling system, which is capable of sampling more than one stream. The chromatograph is calibrated daily using three quantitative standard mixtures. Response factors, based on peak areas, for each gas are adjusted every day to yield the known volume percentage concentration for each species in …
منابع مشابه
Report on First Iranian International Conference on Women’s Health Held June 14-15, 2012 in Shiraz, Iran
متن کامل
آینده بهداشت همگانی
We need effective leadership for provision of enough resources in public health. Recent report of medical institution about public health future include excellent advises for community health nurses activities. In this report not only numerous successes of public health have been identified but also methods which public health leaders can use to complete their mission in community have been exp...
متن کاملMeeting report: GSC M5 roundtable at the 13th International Society for Microbial Ecology meeting in Seattle, WA, USA August 22-27, 2010
This report summarizes the proceedings of the Metagenomics, Metadata, Metaanalysis, Models and Metainfrastructure (M5) Roundtable at the 13th International Society for Microbial Ecology Meeting in Seattle, WA, USA August 22-27, 2010. The Genomic Standards Consortium (GSC) hosted this meeting as a community engagement exercise to describe the GSC to the microbial ecology community during this im...
متن کاملTrip Report for “ 233 rd American Chemical Society Meeting ” Chicago , IL March 25 - 29 , 2007
The 233 ACS meeting was a platform for a large number of lectures and poster sessions covering varied topics of chemistry presented from members of industry and academia. This report highlights various presentations, from the meeting, of interest to those involved in computational chemistry and chemical informatics.
متن کاملGiant Thyroid Fibrosarcoma- A Case Report
Introduction: Thyroid gland fibrosarcomas are extremely rare tumors, and only very few cases have been described in the literature. There are no set recommendations along with follow-ups regarding the treatment of these tumors. Moreover, the prognosis is poor with a very short life expectancy. Case Report: We present an 81-year-old patient who was suffering from increa...
متن کاملEducational accountability in post-conflict settings: a case study of Nepal; Country case study prepared for the 2017/8 Global education monitoring report, Accountability in education: meeting our commitments; 2017
This paper was commissioned by the Global Education Monitoring Report as background information to assist in drafting the 2017/8 GEM Report, Accountability in education: Meeting our commitments. It has not been edited by the team. The views and opinions expressed in this paper are those of the author(s) and should not be attributed to the Global Education Monitoring Report or to UNESCO. The pap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 4 شماره
صفحات -
تاریخ انتشار 1982