Development and Calibration of an Impulse Magnetic Field Measurement System for Lightning Electromagnetic Pulse Investigation

نویسندگان

  • XIAO-MING REN
  • ZHENG-CAI FU
  • WEI SUN
چکیده

In order to evaluate the impulse magnetic field distribution inside buildings truck by lightning or by nearby stokes, a set of measuring system composed of self-made magnetic detection coil and fiber transmission system was developed. The sensitivity coefficient of the optical fiber transmission system was calibrated by sine wave generator. Connecting the output of a portable 8/20μs current generator with a circular coil whose diameter is 0.3 m to compose the magnetic field generator, the detection coil was fixed in the center of the circular coil for calibration. The B/V calibrated coefficient error of the system is less than 3%. A demonstrating application of the developed measurement system is in the investigation of the electromagnetic environment in buildings under direct and nearby lightning strokes. Experimental verification of such application has been carried out on metal frame structure models of building in laboratory. Two scaled metal frame structure models are set up in the laboratory. The measured transient magnetic field distributions inside the building frame structures are verified by comparison of the testing results with the calculated results using the circuit method simulation. In the circuit method, the lightning channel and the building’s metal cage are modeled by a multi-conductor system. Every branch conductor is divided into several suitable segments. The length of each segment is less than one tenth of the wavelength corresponding to the maximum frequency in the equivalent spectrum of the lightning transient current. Each segment is modeled by a coupled π -type lumped circuit. The test results of the developed measurement system coincide with the calculated results well. Under the situation of nearby lightning strokes, the developed measurement system is also used for the investigation of the shielding effectiveness of the building frame structure. The test results of the shielding effectiveness on the metal frame structure model shows that the effectiveness coefficient increases with the decrease of grid width of the frame. While the width of the grid changes from 0.5m to 0.25m, there is an increase of shielding effectiveness of approximately 10.2%. While the width of grid changes from 0.25 m to 0.125 m, the shielding effectiveness increases about 5%. To simulate the situation when metal plate wall exists in the building, 0.5 mm steel plate was attached on the frame structure model. Under such situation, the shielding effectiveness increases to 4.9. The application experiments of the developed measurement system show that it can fulfill the requirements of lightning impulse magnetic field measurement. Key-Words: impulse magnetic field, calibration, magnetic field generator, magnetic field measurement, lightning protection, fiber transmission system

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electromagnetic Field Due to Lightning Strikes to Mountainous Ground

The produced electric and magnetic fields due to lightning strikes to mountainous ground are determined in this paper. For the sake of simplicity a cone-shaped ground with finite conductivity is assumed to represent a natural nonflat ground. By this assumption, we deal with an axillary symmetrical structure so we use the cylindrical 2D-FDTD to save the simulation memory and time, dramatically. ...

متن کامل

Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems

In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...

متن کامل

Sensors for Measurement of Intense Electromagnetic Pulses

Fast, large-amplitude pulses are encountered in-the nuclear electromagnetic pulse (EMP), lightning, various pulse-power machinery, and charged particle ke~ms. In the context of the EMP program various accurate, broad-band senrs have been developed. The principal types of these sensors have been ..signedto measure electric and magnetic fields, current densities, currents, and voltages. Often it ...

متن کامل

Broadband radio interferometer utilizing a sequential triggering technique for locating fast-moving electromagnetic sources emitted from lightning

A broadband radio interferometer to investigate the location of fast-moving electromagnetic (EM) sources emitted from lightning discharges has been designed. A sequential triggering technique was applied to the system for recording the data of broadband electromagnetic pulses from 25 to 250 MHz. Once the electromagnetic pulse is detected and its amplitude exceeds a threshold level, the triggeri...

متن کامل

AN INVESTIGATION ON THE EFFECT OF ELECTROMAGNETIC FORCE ON THE CHARACTERISTICS OF ELECTRODEPOSITED Ni/Al2O3 COMPOSITE COATINGS

Electrochemical coating processes are significantly affected by applied magnetic fields due to the generation of electromagnetic forces. The present research work has been undertaken to study the effect of coating parameters such as current density and alumina concentration on the characteristics of Ni-Al2O3 composite coating under static magnetic field. Ni-Al2O3 composite coating was applied o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010