A Micro-fluidic System for the Evaluation of Blood Compatibility of Polymers

نویسندگان

  • C. Minelli
  • A. Kikuta
  • A. Yamamoto
چکیده

We present a new technique for the evaluation of polymer blood compatibility that makes use of a microchannel array flow analyzer and we describe and characterize the flow dynamics of this instrument. The blood compatibility of four polymers is quantitatively and qualitatively assessed and the results discussed. The blood is allowed to flow through the channels of a polymer coated micro-fluidic chip under adjustable pressure. The chip surface is investigated using optical microscopy during the blood flow and by scanning electron microscopy afterwards. Polymers known for having good blood compatibility exhibited higher flow rate values. Platelets were observed adhering, aggregating and obstructing the channels of the chips coated with polymers known for having poor blood compatibility. This technique has remarkable qualities such as a small blood volume requirement for material tests (100 μL), tuneable flow regimes and the use of human blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Short Review on Fabrication Methods of Micro-Cantilever for Ionic Electroactive Polymer Sensors/Actuators

   Micro-electroactive polymers have wide applications from industry to healthcare. Artificial muscles, microvalves, microswitches, haptic sensing, blood pressure and pulse monitoring are some potential applications for micro-electroactive polymers. The most advantage of micro-electroactive polymers as sensors and actuators is bio-compatibility and low power threshold for large deformations...

متن کامل

Preparation and Evaluation of Blood Compatibility of Novel Epoxy-Modified Polyurethanes

      In order to prepare polyurethane elastomers with acceptable physical properties and good biocompatibility, novel polyurethane networks were synthesized via curing reaction of epoxy-terminated polyurethane prepolymers (EUPs) with hexamethylene diamine. EUPs were prepared from reaction of glycidol with NCO-terminated polyurethanes (ITPs). ITPs were also synthesized from reaction of one equi...

متن کامل

Design and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array

In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...

متن کامل

Micromachined Fluidic Couplers

A family of self-aligning micromachined fluidic couplers are presented here. Bulk micromachined and DRIE processed silicon structures have been investigated as a means of providing external connections via fused silica capillaries for MEMS fluidic devices. These couplings can have arbitrary geometry, ensuring compatibility with most fluidic ports. In addition, performance exceeds typical requir...

متن کامل

A micro-fluidic study of whole blood behaviour on PMMA topographical nanostructures

BACKGROUND Polymers are attractive materials for both biomedical engineering and cardiovascular applications. Although nano-topography has been found to influence cell behaviour, no established method exists to understand and evaluate the effects of nano-topography on polymer-blood interaction. RESULTS We optimized a micro-fluidic set-up to study the interaction of whole blood with nano-struc...

متن کامل