X-Ray energy dependence of the dose response of SIRAD radiation dosimeters.
نویسندگان
چکیده
SIRADs (self-indicating instant radiation alert dosimeters) are designed to measure accident radiation doses. As the energy of radiation is usually unknown in such situations, a detector with a weak energy dependence of its response to dose would be ideal. We have studied the energy dependence of the dose response of SIRADs in the range from 50kVp to 10MV, which corresponds to photon equivalent energies from 25.5keV to 2.2MeV. The response to the same dose at 25.5keV is (29+/-4)%(+/-1s) lower than the response at 1.4MeV. The response to a dose slowly increases with radiation energy. This energy dependence is relatively weak in comparison with the dependence for radiographic films and similar in magnitude to the dependence for lithium fluoride thermoluminescence dosimeters. This energy dependence of the response diminishes the accuracy of dose assessments in radiation fields of unknown energy, but does not significantly compromise the core ability of the devices to provide visual estimates of radiation doses.
منابع مشابه
A Validation Study on Radiation properties of a Novel LiF: Mg, Ti Known as IAP-100
Introduction: LiF dosimeter has the most application in medicine. This study aimed to evaluate some dosimetric properties of a novel LiF: Mg, Ti. Materials and Methods: An ELEKTA Precise linear accelerator was used to calibrate dosimeters at 6 MV. In this survey, responses of dosimeters were evaluated up to 1000 cGy. Background effect was investigated in two different dosimeter states includin...
متن کاملEvaluating the effect of energy on calibration of thermo-luminescent dosimeters 7-LiF:Mg,Cu,P (GR-207A)
Background: 7-LiF: Mg,Cu,P (GR-207A) is one kind of thermo-luminescent dosimeters (TLD) which can be used in diagnostic radiology and radiotherapy applications. Because of having suitable properties such as good sensitivity, small size and being tissue equivalent, thermo-luminescent dosimetry has been one of the most important techniques in medicine over many years. Choosing a correct energy fo...
متن کاملVisible absorption spectra of radiation exposed SIRAD dosimeters.
SIRAD badge dosimeters are a new type of personal dosimeter designed to measure radiation exposure up to 200 R and give a visual qualitative measurement of exposure. This is performed using the active dosimeter window, which contains a radiochromic material amalgamated in the badge assembly. When irradiated, the badges active window turns blue, which can be matched against the given colour char...
متن کاملVerification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams
Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...
متن کاملAn in-vivo study on the energy dependence of X-ray biological effectiveness
Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 65 7 شماره
صفحات -
تاریخ انتشار 2007