Multivariate delta check method for detecting specimen mix-up.

نویسندگان

  • Y Iizuka
  • H Kume
  • M Kitamura
چکیده

Among laboratory mistakes, "specimen mix-up" is the most frequent and the most serious. According to the Clinical Chemistry Laboratory Error Report of Toranomon Hospital, specimen mix-up was often detected when there were many large discrepancies between the results of a test and the results of a previous test. We present here a checking method to detect specimen mix-up. The method, which we call the "multivariate delta check" method, is an extension of the "delta check" method first presented by Nosanchuk and Gottmann (Am. J. Clin. Pathol. 62:707, 1974). Clinical evaluation has demonstrated the effectiveness of the method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential application of rate and delta check on selected clinical chemistry tests.

Through the present delta value check used in quality control programs is a powerful tool for detecting random errors in clinical chemistry analysis, it has some problems, such as missed true errors and delays in reporting time, because it also has the potential of showing erroneous positive results. Recently, new calculation methods for delta check with delta difference, delta percent change, ...

متن کامل

Location of monoclonal peak as a tool in checking specimen integrity

OBJECTIVES Serum protein electrophoresis is a commonly used test in the diagnosis and follow-up of patients with monoclonal gammopathies. The practice of documenting the location of the peak may serve as delta check flags in SPEP samples. METHODS We report on the inconsistent finding on two tests performed about three months apart. The inconsistency was discovered due to recognition of the ch...

متن کامل

Confusion—specimen mix-up in dermatopathology and measures to prevent and detect it

Maintaining patient identity throughout the biopsy pathway is critical for the practice of dermatology and dermatopathology. From the biopsy procedure to the acquisition of the pathology report, a specimen may pass through the hands of more than twenty individuals in several workplaces. The risk of a mix-up is considerable and may account for more serious mistakes than diagnostic errors. To pre...

متن کامل

A laboratory study on mix design to properly resemble a jointed brittle rock

In this paper attempts have been done to create a mortar with relatively high uniaxial compressive strength (UCS), easy casting, high flexibility, instant hardening, low cost and easy availability. The main use of this material is to physically model the mechanical behavior of jointed rock-like blocks. The effect of four parameters such as joint roughness coefficient (JRC), bridge length (L), b...

متن کامل

Online Monitoring and Fault Diagnosis of Multivariate-attribute Process Mean Using Neural Networks and Discriminant Analysis Technique

In some statistical process control applications, the process data are not Normally distributed and characterized by the combination of both variable and attributes quality characteristics. Despite different methods which are proposed separately for monitoring multivariate and multi-attribute processes, only few methods are available in the literature for monitoring multivariate-attribute proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 11  شماره 

صفحات  -

تاریخ انتشار 1982