Biomechanical analysis of femoral tunnel pull-out angles for anterior cruciate ligament reconstruction with bioabsorbable and metal interference screws.
نویسندگان
چکیده
BACKGROUND Fixation strength of metal and bioabsorbable interference screws has not been evaluated while varying the anterior cruciate ligament graft tension angle. HYPOTHESIS There is no difference in fixation strength between 2 types of interference screws for anterior cruciate ligament graft fixation while the graft tension angle is varied relative to the femoral tunnel. STUDY DESIGN Controlled laboratory study. METHODS Forty-eight anterior cruciate ligament reconstructions were performed using immature porcine femurs stripped of soft tissue and doubled-over porcine flexor digitorum profundus tendon grafts. Specimens were randomized to bioabsorbable or titanium interference screw fixation. Specimens were randomized to one of three pull angles (0 degrees , 30 degrees , 60 degrees ) representing loading at different knee flexion angles (n = 8/group). Reconstructed ligaments were tensioned to 10 N followed by 200 loading cycles between 10 and 150 N and a final failure test. Construct elongation (mm) at 100 and 200 cycles and failure load (N) were analyzed using a 2-way analysis of variance (P < .05). RESULTS Screw material interacted significantly with graft tension angle, as the bioabsorbable screw specimens demonstrated significantly greater fixation strength when tensioned at greater angles. Specimens fixed with bioabsorbable screws showed significantly less elongation at both 100 and 200 cycles and significantly greater failure load compared with titanium screws. CONCLUSION Bioabsorbable interference screws acutely have increased fixation strength compared with titanium interference screws for anterior cruciate ligament grafts loaded at greater tension angles. CLINICAL RELEVANCE The strength of anterior cruciate ligament reconstruction fixation increases with increasing divergence between the tension angle and femoral tunnel, a condition seen when the knee approaches full extension.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملBiomechanical Study of Transcortical or Transtrabecular Bone Fixation of Patellar Tendon Graft with Bioabsorbable Pins in Acl Reconstruction in Sheep.
OBJECTIVE To determine the initial resistance of fixation using the Rigid Fix(®) system, and compare it with traditional fixation methods using metal interference screws; and to evaluate the resistance of the fixation with the rigid fix system when the rotational position of the bone block is altered in the interior of the femoral tunnel. METHODS forty ovine knee specimens (stifle joints) wer...
متن کاملMagnetic resonance imaging analysis of the bioabsorbable Milagro™ interference screw for graft fixation in anterior cruciate ligament reconstruction
Ligament graft fixation with bioabsorbable interference screws is a standard procedure in cruciate ligament replacement. Previous screw designs may resorb incompletely, and can cause osteolysis and sterile cysts despite being implanted for several years. The aim of this study was to examine the in vivo degradation and biocompatibility of the new Milagro interference screw (Mitek, Norderstedt, G...
متن کاملMagnesium inference screw supports early graft incorporation with inhibition of graft degradation in anterior cruciate ligament reconstruction
Patients after anterior cruciate ligament (ACL) reconstruction surgery commonly encounters graft failure in the initial phase of rehabilitation. The inhibition of graft degradation is crucial for the successful reconstruction of the ACL. Here, we used biodegradable high-purity magnesium (HP Mg) screws in the rabbit model of ACL reconstruction with titanium (Ti) screws as a control and analyzed ...
متن کاملFunctional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study
Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of sports medicine
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2007