Gadolinium contrast media are more nephrotoxic than a low osmolar iodine medium employing doses with equal X-ray attenuation in renal arteriography: an experimental study in pigs.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES To investigate in a unilaterally nephrectomized porcine model whether gadolinium contrast media (Gd-CM) are less nephrotoxic than iodine media (I-CM) in x-ray arteriography of a kidney made temporarily ischemic by arterial balloon occlusion. MATERIALS AND METHODS In a noncrossover design, 3 mL of each test solution were injected in eight pigs (mean weight 19 kg) at a rate of 20 mL/min into the right renal artery at the start of a 10-minute period of ischemia. In group 1 (40 pigs) we injected 0.5 M gadopentetate, 0.5 M gadodiamide, 0.5 M iohexol (190 mg I/mL), 0.18 M iohexol (70 mg I/mL; with an x-ray attenuation equal to that of 0.5 M Gd-CM at 80 kV), and saline. In group 2 (24 pigs), we tested 0.18 M iohexol with ischemia and saline with and without ischemia. Gd- and iodine contrast media functioned as markers of glomerular filtration rate (GFR). When saline was tested, a low dose of iohexol (3 mL per pig; 300 mg I/mL) was injected as GFR marker intravenously in group 1 and into the renal artery in group 2. The plasma half-life elimination times of the CM 1-3 hours after injection were used to compare the effects of the different test solutions on GFR. Longer half-life means lower GFR. RESULTS Group 1: median plasma half-life elimination time of the GFR marker was 3 340 minutes after injection of 0.5 M gadopentetate, 256 after 0.5 M gadodiamide, 179 after 0.5 M iohexol, 143 after 0.18 M iohexol, and 133 minutes after saline. All differences except that between 0.18 M iohexol and saline were statistically significant (P < .01). Group 2: median plasma half-life was 174 minutes after 0.18 M iohexol with ischemia, 196 minutes after saline with ischemia, and 195 minutes after saline without ischemia. There were no significant differences between the test solutions in group 2 (P > .05). CONCLUSION In pigs, 0.5 M Gd-CM were more nephrotoxic than both equal-attenuating (70 mg I/mL) and equimolar (190 mg I/mL) concentrations of the I-CM iohexol. These results do not support the "off-label" use of Gd-CM for renal x-ray arteriography in man instead of commercially available concentrations of iodine contrast media at 140, 150 and 180 mg I/mL or diluted to 70 mg I/mL.
منابع مشابه
Gadolinium contrast media are more nephrotoxic than a low osmolar iodine medium employing doses with equal x-ray attenuation in renal arteriography: An experimental study
متن کامل
Histomorphological changes after renal X-ray arteriography using iodine and gadolinium contrast media in an ischemic porcine model.
BACKGROUND Gadolinium contrast media (Gd-CM) are regarded as non-nephrotoxic or considerably less nephrotoxic than iodine contrast media (I-CM), and have therefore come to be used as a substitute for I-CM in patients with renal insufficiency in a variety of radiographic examinations. PURPOSE To investigate renal histomorphological changes caused by Gd-CM in comparison with I-CM after renal X-...
متن کاملAre gadolinium-based contrast media really safer than iodinated media for digital subtraction angiography in patients with azotemia?
Gadolinium chelates, intended as intravenous contrast media for magnetic resonance imaging, have been regarded as nonnephrotoxic and recommended to replace iodinated contrast media in patients with azotemia who are undergoing digital subtraction angiography (DSA). High intraarterial doses (up to 220 mmol of gadodiamide) have been used, with a 40% incidence of nephropathy. The authors discourage...
متن کاملIntra-arterial and intravenous applications of Iosimenol 340 injection, a new non-ionic, dimeric, iso-osmolar radiographic contrast medium: phase 2 experience
BACKGROUND Iosimenol 340 injection is a new, dimeric, iso-osmolar, iodinated contrast medium for X-ray angiography. PURPOSE To compare the safety and efficacy of iosimenol injection to iodixanol injection in two randomized, controlled phase 2 trials. MATERIAL AND METHODS One hundred and forty-four adult patients were enrolled in the two trials, one for evaluation during arteriography and th...
متن کاملCan prolonged pregnancy complicate hypothyroidism?
Contrast media-induced nephropathy (CIN) is a well-known complication of radiological examinations employing iodine contrast media (I-CM). The rapid development and frequent use of coronary interventions and multi-channel detector computed tomography with concomitant administration of relatively large doses of I-CM has contributed to an increasing number of CIN cases during the last few years. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic radiology
دوره 11 11 شماره
صفحات -
تاریخ انتشار 2004