Towards practical time-of-flight secondary ion mass spectrometry lignocellulolytic enzyme assays

نویسندگان

  • Robyn E Goacher
  • Alex Yi-Lin Tsai
  • Emma R Master
چکیده

BACKGROUND Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a surface sensitive mass spectrometry technique with potential strengths as a method for detecting enzymatic activity on solid materials. In particular, ToF-SIMS has been applied to detect the enzymatic degradation of woody lignocellulose. Proof-of-principle experiments previously demonstrated the detection of both lignin-degrading and cellulose-degrading enzymes on solvent-extracted hardwood and softwood. However, these preliminary experiments suffered from low sample throughput and were restricted to samples which had been solvent-extracted in order to minimize the potential for mass interferences between low molecular weight extractive compounds and polymeric lignocellulose components. RESULTS The present work introduces a new, higher-throughput method for processing powdered wood samples for ToF-SIMS, meanwhile exploring likely sources of sample contamination. Multivariate analysis (MVA) including Principal Component Analysis (PCA) and Multivariate Curve Resolution (MCR) was regularly used to check for sample contamination as well as to detect extractives and enzyme activity. New data also demonstrates successful ToF-SIMS analysis of unextracted samples, placing an emphasis on identifying the low-mass secondary ion peaks related to extractives, revealing how extractives change previously established peak ratios used to describe enzyme activity, and elucidating peak intensity patterns for better detection of cellulase activity in the presence of extractives. The sensitivity of ToF-SIMS to a range of cellulase doses is also shown, along with preliminary experiments augmenting the cellulase cocktail with other proteins. CONCLUSIONS These new procedures increase the throughput of sample preparation for ToF-SIMS analysis of lignocellulose and expand the applications of the method to include unextracted lignocellulose. These are important steps towards the practical use of ToF-SIMS as a tool to screen for changes in plant composition, whether the transformation of the lignocellulose is achieved through enzyme application, plant mutagenesis, or other treatments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MALDI-TOF MS Coupled with Collision-Induced Dissociation (CID) Measurements of Poly(methyl methacrylate)

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is one of themost fundamental analysis techniques for proteins, peptides, and synthetic polymers to date. Along with field desorption (FD), fast atom bombardment (FAB), laser desorption coupled with time-of-flight (LD-TOF), secondary ion mass spectrometry coupled with time-of-flight (SIMS-TOF), and electr...

متن کامل

Analysis By Time-Of-Flight Secondary Ion Mass Spectroscopy or Nuclear Products In Hydrogen Penetration Through Palladium

Elemental analysis was performed for the palladium foil through which the hydrogen gas penetrated. We analyzed sample surface by Time-of-Flight secondary ion mass spectroscopy and searched for newly produced elements during the gas permeation process. Significant increase of the counts for Cr, Fe, Cu and Ag were found after the permeation. These elements could have been produced by nuclear tran...

متن کامل

Synthesis and characterisation of PEG-peptide surfaces for proteolytic enzyme detection

Peptide surfaces were obtained by the covalent immobilisation of fluorescently labelled pentapeptides carboxyfluorescein-glycine-arginine-methionine-leucine-glycine, either directly or through a poly(ethylene glycol) (PEG) linker on modified silicon wafers. Each step during the preparation of the peptide surfaces was confirmed by several surface characterisation techniques. Time-of-flight secon...

متن کامل

Instruments AnLIFcharacterizationofsupersonicBO ( X 2 � + ) andCN ( X 2 � + ) radical sourcesforcrossedbeamstudies

New method for the calibration of three-dimensional atom-probe mass spectra Energy distribution and spatial structure of electrosprays of ionic liquids in vacuo Recent results with Au ions from a multiampere electron beam ion source at Brookhaven National Laboratory (invited abstract) Time-of-flight secondary ion mass spectroscopy for surface analysis of insulators using a cluster ion beam Quan...

متن کامل

Wet-cleaning of MgO(001): Modification of surface chemistry and effects on thin film growth investigated by x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectroscopy

Arnaud Le Febvrier, Jens Jensen and Per Eklund, Wet-cleaning of MgO(001): Modification of surface chemistry and effects on thin film growth investigated by x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectroscopy, Journal of Vacuum Science & Technology. A. Vacuum, Surfaces, and Films, 2017. 35(2). http://dx.doi.org/10.1116/1.4975595 Copyright: AIP Publishing http://ww...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013